Duratool D03126 Handbuch - Seite 5
Blättern Sie online oder laden Sie pdf Handbuch für Multimeter Duratool D03126 herunter. Duratool D03126 8 Seiten. Digital multimeter with backlight
GENERAL SPECIFICATION
Accuracy is specified for a period of one year after calibration and at 18 to 28°C (64°F
to 82°F) with relative humidity to 80%.
Max. voltage between terminals and
earth ground
Fuse Protection
Power
Display
Measuring Method
Overrange Indication
Polarity Indication
Operating Environment
Storage Temperature
Low battery indication
Size
Weight
DC VOLTAGE
Range
200mV
2V
20V
200V
600V
Overload protection: 250V rms. For 200mV range and 600V dc or rms, ac for other
ranges.
DC CURRENT
Range
200µA
2mA
20mA
200mA
10A
Overload protection: F 200mA/250V fuse (10A range unfused).
CAT II 600V
F 200mA / 250V
9V battery, NEDA 1604 or 6F22
LCD, 1999 counts, updates 2-3 seconds
Dual-slope integration A/D converter
Only figure "1" on the display
"-" displayed for negative polarity
0°C to 40°C
-10°C to 50°C
"
" appears on the display
138mm x 69mm x 31mm
Approx 170g
Resolution
100µV
1mV
10mV
100mV
1V
Resolution
0.1µA
1µA
10µA
100µA
10mA
5
Accuracy
± 0.5% of rdg ± 2 digits
± 0.5% of rdg ± 2 digits
± 0.5% of rdg ± 2 digits
± 0.5% of rdg ± 2 digits
± 0.8% of rdg ± 2 digits
Accuracy
± 1% of rdg ± 2 digits
± 1% of rdg ± 2 digits
± 1% of rdg ± 2 digits
± 1.5% of rdg ± 2 digits
± 3% of rdg ± 2 digits