AC VOLTAGE
Range
200V
600V
RESPONSE: Average responding, calibrated in rms of a sine wave.
FREQUENCY RANGE: 45Hz ~ 450Hz.
OVERLOAD PROTECTION: 1000V DC or 750V rms for all ranges.
CONTINUITY
Range
OVERLOAD PROTECTION: 15 seconds maximum 220V RMS.
DC CURRENT
Range
2000µA
20mA
200mA
5A
OVERLOAD PROTECTION: F0.5A/500V and F5A/250V fuse.
MEASURING VOLTAGE DROP: 200mV.
Resolution
100mV
1V
Built in buzzer sounds if resistance is less
than 30±20
Resolution
1µA
10µA
100µA
10mA
4
Accuracy
±(2.0% of rdg +10D)
Description
Accuracy
±(1.8% of rdg +2D)
±(2.0% of rdg +2D)
±(2.0% of rdg +10D)