Duratool D03405 Handbuch - Seite 8

Blättern Sie online oder laden Sie pdf Handbuch für Messgeräte Duratool D03405 herunter. Duratool D03405 8 Seiten. Handheld anemometer

Comfort Level
Range
Wind Chill
11. Specifications
Recommended operating temperatures :
Temperature checking interval :
Wind speed measuring range Barometric :
Measuring range :
Altitude measuring range :
Power source :
Battery life :
Dimensions (L x W x H) :
12. Troubleshooting Guide
Problem
Wind Chill shows --.-
Impeller appears imbalanced.
Vane is noisy at high speed.
Display is dim or disappears.
INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL &
ELECTRONIC EQUIPMENT.
When this product has reached the end of its life it must be treated as Waste Electrical & Electronic
Equipment (WEEE). Any WEEE marked products must not be mixed with general household waste,
but kept separate for the treatment, recovery and recycling of the materials used. Contact your local
authority for details of recycling schemes in your area.
Comfort level is the body's effect based on ranges of temperature.
Range is defined as the amount or extent a value can be measured.
Wind chill is the felt air temperature on exposed skin due to wind. It
measures the effect of wind on air temperature. The wind chill
temperature is usually lower than the air temperature, since the air
temperature is usually lower than the human body temperature.
-29.9°C to +59°C with 0.1°C resolution
(-21.8 °F to 138.2 °F with 0.2° resolution)
("---"displayed if outside this range)
every 1 minute
1.5m/s - 30 m/s (3.3 mph - 67mph)
600-1100hPa
-500m-3000m
1 x 3V lithium cell (CR2032)
Approximately 12 months
50 x 18 x 140 mm (2" x 0.7" x 5.5")
The wind chill is meaningless above 50 °F, and is not
displayed (out of range, or - -.-).
It is normal for the impeller to oscillate as it comes to a
stop, and it is not imbalanced. The unit contains a very
small magnet that responds to the earth's magnetic
fields. This does not affect the accuracy of the wind
speed readings and only apparent when slowing or
accelerating.
This is normal for the vane to vibrate at high speed.
Do not operate above 67 mph.
Above 67 mph, the unit will display ---.
The LCD display will not operate below approximately
14 °F. Use the warmth of your body or environment for
use in cold weather conditions, or Battery is dead.
Replace the battery.
1. T
Solution
PO Box 13362 Dublin 2
Made in China.
PR2 9PP