5. Analog Input Connection Diagram

EXT
Sensor
A common analog GROUND(AGND) works input basis for the SE connection. At this time, the input
channel has total 8 channels.
EXT
Sensor
An analog DI connection is a difference between two input channel pairs. At this time, the input pairs
connect according (CH0 <-> CH1), (CH2 <-> CH3), (CH4 <-> CH5), (CH6 <-> CH7). So, in case of DI
connection have total 4 input channels.
In addition, mixed connection of SE, DI is supported. If SE use three inputs and DI use two inputs,
the method of connection of SE input is CH0~CH2, DI (CH4 <-> CH5), (CH6 <-> CH7) as it is usable.
ADC CH0-7
AGND
[Figure 5-1. Analog SE (Single Ended) Input Connection]
ADC CH0/6
ADC CH1/7
[Figure 5-2. Analog DI (Differential Input) Connection]