ceaselessly, especially for child and patient of poor perfusion or immature
dermographia by light collimation. Iris recommended that the device should not be
applied to the same finger for over 2 hours.
 Make sure no contamination or scar exists in the site where the device is placed.
Otherwise, the measured result may be incorrect because the signal received by the
sensor is affected.
 When used on different patients, the device is prone to crossed contamination, which
should be prevented and controlled by the user. Disinfection is recommended before
using the device on other patients.
NOTE
 Do not perform SpO2 monitoring and NIBP measurements on the same arm
simultaneously. Obstruction of blood flow during NIBP measurements may adversely
affect the reading of the SpO2 value.
 The patient's fingernail should not be too long, otherwise the finger cannot be
inserted into the sensor to a suitable depth and the SpO2 measurements may be
inaccurate.
8. Maintenance
System Check
Before using the device, perform the following steps:
 Check if there is any mechanical damage;
 Check if all the functions of the device can work normally so as to make sure that the
device is in proper working condition;
 Check if the battery energy is sufficient. If the device can not be powered on, or when
powering on, the battery capacity bar is 0 level or the low battery power indicator is red
and flashes, replace the batteries with good ones.
In case of any damage, abnormal function, hidden safety danger or exception, do not use
the device on patient. Contact the technician in your hospital or the manufacture
immediately.
Make sure the qualified service personnel have implemented a complete inspection,
including the functional safety check, after the device has been used for 6-12 consecutive
months, or after device servicing or system upgrading. This is to ensure the normal
operation of the system.
CAUTION
Take out the batteries if the device is not in used for a long time.
General Cleaning
The device should be cleaned on a regular basis. When it is polluted by dust, oil, sweat or
blood etc., it should be cleaned at once. If there is heavy pollution or lots of dust and sand
in your place, the device should be cleaned more frequently. Before cleaning the device,
consult your hospital's regulations for cleaning, disinfecting and sterilizing equipment. The
exterior surfaces of the device may be cleaned gently with a clean and soft cloth, sponge or
cotton swap, dampened with a non-erosive cleaning solution. Drying off excess cleaning
solution before cleaning the device is recommended.
WARNING
 Power off the device before cleaning.
Examples of suitable cleaning solutions are as follows:
 Diluted soap water
10