4B HTAS1V34 Betriebshandbuch - Seite 10

Blättern Sie online oder laden Sie pdf Betriebshandbuch für Zubehör 4B HTAS1V34 herunter. 4B HTAS1V34 20 Seiten. Wda sensor belt alignment / motion & broken / slack chain monitor

4B HTAS1V34 Betriebshandbuch
WDA sensors can be installed on the front of the elevator leg if side mounting in not possible. 4B
recommends that all sensors be placed either on the side or on the front, but not in combinations.
METAL ELEVATOR BUCKET SIDE MOUNTING DIAGRAMS -
PULSE
NO PULSE
NOTE -
If using stainless steel elevator
buckets and bolts (non-ferrous),
use PTFE coated steel fender
washers (ferrous) between the belt
and bucket. Mount WDA sensor
on the back side of the leg to target
the ferrous bolts / washers.
Alternatively, 400 series stainless
steel bolts (magnetic) can be use.
NOTE
NORMAL RUNNING
Metal Elevator Bucket
BELT MISALIGNMENT
Metal Elevator Bucket
PAGE 10
PULSE
PULSE
Figure 2 -
Recommended WDA
Sensor Placement For
Metal Elevator Buckets
Belt
WDA Sensor
Probe Position
Figure 3 -
Elevator Leg Side View