APLOS R0-5050 Gebrauchsanweisung - Seite 15
Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Water Filtration Systems APLOS R0-5050 herunter. APLOS R0-5050 20 Seiten. 5 stage reverse osmosis drinking water system, 50gpd
9. Membrane Replacement Guide
1.
Turn off water supply to the system (feed valve 5), shut off the tank valve 6.
Open the purified water faucet 3 to relieve permeate pressure.
2.
Disconnect the white tube from the inlet in membrane housing cap.
3.
Unscrew the membrane housing cap.
4.
Remove the used reverse osmosis membrane 11 (remember which end of
5.
the membrane goes where).
6.
Lubricate rubber seals of the fresh replacement membrane and
membrane housing cap sealing.
CAUTION! To avoid damage to the membrane, only use food grade
glycerol as lubricant.
7.
Install the fresh membrane into the housing, observing its direction and
position of the tube.
CAUTION! Ensure to wear latex gloves when installing the reverse
osmosis membrane. Avoid direct contact with the membrane.
8.
Screw on the housing cap.
9.
Connect the white tube to the membrane housing inlet.
10.
Close drinking water faucet 3.
11.
Open the tank valve 6.
12.
Open the feed valve 5.
13.
Once the tank is full (you will hear the water stop flowing), drain all water
from the tank into the sink by opening faucet 3. When the water stops
running, close the purified water faucet 3 so that the tank starts to re-fill.
Depending on the pressure in your water mains, filling may take 1.5 to 3
hours. After the second tank re-fill, you can safely use the purified water.
Membrane
Cap of the membrane housin
White Tube
15