6.0 Maintenance Schedule

The following periodic maintenance schedule is the suggested minimum requirements and
at minimum intervals; accumulated hours or monthly period, whichever comes sooner. If you
hear a noise or see any indication of possible failure - cease operation immediately and
inspect, correct and/or replace parts as required. Following these maintenance procedures
is the key to prolonging the life or your lift. We highly recommend using an APlusLift
authorized technician for all repairs and modifications.
I F AT AN Y T I M E Y OU ARE N OT SU RE OF T H E SAFE OPERAT I ON OF T H E
LI FT, STOP U SING I T AN D CALL Y OU R DI ST RI BU T OR FOR ASSI STAN CE.
Warning OSHA and ANSI require APlusLift authorized users
to inspect lifting equipment at the start of every shift. These
and other daily periodic inspections are the responsibility of
the user.
6.1 Daily Pre-Operation Check
The user should at least perform the following checks daily.
Da ily c he c k of sa fe t y loc k ing/la t c h syst e m is ve r y im port a nt - t he disc ove r y
of de vic e fa ilure c ould sa ve you from e x pe nsive prope rt y da m a ge , lost
produc t ion t im e , se rious pe rsona l injur y a nd e ve n de a t h.
Check to ensure that the safety latches are freely moving and full engaged.
Check pneumatic connections, and hoses for leakage.
Check the cylinder rod, if it becomes dry, lightly oil it.
Check all bolts, nuts, shafts, retaining clips, retainer rings, set screws and screws, ensure
they are aligned (grooves), secured, and tightened properly. Pivot shaft set screws should
always be checked to ensure that they are tight.
Keep lift free of dirt, grease or any other corrosive substances.
You should use an oil air regulator to keep the cylinder dry and clean from contamination of
the air compressor
Release the water from your air compressor daily to ensure that no water contaminates the
foot pedal, hose and hydraulic cylinder.
The oiler should supply a mist of oil to the foot pedal, hose and hydraulic cylinder for
lubrication every 10 cycles up and down.