Apogee SP-214-SS Benutzerhandbuch - Seite 6

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Zubehör Apogee SP-214-SS herunter. Apogee SP-214-SS 19 Seiten. Pyranometer

Apogee SP-214-SS Benutzerhandbuch

SPECIFICATIONS

ISO 9060:2018
Power Supply
Sensitivity
Sensitivity from serial
numbers 9997 and above
Calibration Factor
Calibration Factor from
serial numbers 9997 and
above
Calibration Uncertainty
Calibrated Output Range
Measurement
Repeatability
Long-term Drift (Non-
stability)
Non-linearity
Non-linearity from Serial
numbers 9997 and above
Response Time
Field of View
Spectral Range
Directional (Cosine)
Response
Temperature Response
Operating Environment
Dimensions
Mass
Cable
Calibration Traceability
Apogee Instruments SP series pyranometers are calibrated through side-by-side comparison to the mean of four
Apogee model SP-110 transfer standard pyranometers (shortwave radiation reference) under high intensity
discharge metal halide lamps. The transfer standard pyranometers are calibrated through side-by-side comparison
to the mean of at least two ISO-classified reference pyranometers under sunlight (clear sky conditions) in Logan,
Utah. Each of four ISO-classified reference pyranometers are recalibrated on an alternating year schedule (two
instruments each year) at the National Renewable Energy Laboratory (NREL) in Golden, Colorado. NREL reference
standards are calibrated to the World Radiometric Reference (WRR) in Davos, Switzerland.
Class C (previously known as second class)
7 to 24 V DC with a maximum current draw of 22 mA (2 mA quiescent current draw)
-2
78 W m
per mA (reciprocal of sensitivity) with an offset of 4 mA
-2
125 W m
per mA (reciprocal of sensitivity) with an offset of 4 mA
± 5 % (see calibration Traceability below)
Less than 1 % (up to 1250 W m
Less than 1 % (up to 2000 W m
360 to 1120 nm (wavelengths where response is 10 % of maximum; see Spectral
± 5 % at 75° zenith angle (see Cosine Response below)
0.04 ± 0.04 % per C (see Temperature Response below)
-40 to 70 C; 0 to 100 % relative humidity; can be submerged in water up to depths of
5 m of four conductor, shielded, twisted-pair wire; TPR jacket; pigtail lead wires;
stainless steel (316), M8 connector located 25 cm from sensor head
SP-214-SS
0.0128 mA per W m
0.008 mA per W m
4 to 20 mA
Less than 1 %
Less than 2 % per year
-2
; maximum radiation measurement is 1250 W m
-2
; maximum radiation measurement is 2000 W m
Less than 1 ms
180°
Response below)
30 m
24 mm diameter, 33 mm height
90 g (with 5 m of lead wire)
-2
-2
-2
)
-2
)