SPECIFICATIONS

Input Voltage Requirement: 4.5 to 24 V DC
Current Drain: 1.1 mA (quiescent), 6 mA (transmitting)
Calibration Uncertainty (-20 to 65 C): 0.2 C, when target and detector temperature are within 20 C
Calibration Uncertainty (-40 to 80 C): 0.5 C, when target and detector temperature are different by
more than 20 C (see Calibration Traceability below)
Measurement Repeatability: < 0.05 C
Stability (Long-term Drift): less than 2 % change in slope per year when germanium filter is maintained
in a clean condition (see Maintenance and Recalibration section below)
Response Time: 0.6 s, time for detector signal to reach 95 % following a step change; fastest data
transmission rate for SDI-12 circuitry is 1 s
Field of View: 22° half angle (SI-411)
18° half angle (SI-421)
14° half angle (SI-431)
32° horizontal half angle; 13° vertical half angle (SI-4H1)
Spectral Range: 8 to 14 µm; atmospheric window (see Spectral Response below)
Operating Environment: -45 to 80 C
Dimensions: 2.3 cm diameter and 6.0 cm length
Mass: 190 g (with 5 m of lead wire)
Cable: 5 m of four conductor, shielded, twisted-pair wire.
Additional cable available in multiples of 5 m
Santoprene rubber jacket (high water resistance, high UV stability, flexibility in cold conditions)
Pigtail lead wires
0 to 100 % relative humidity (non-condensing)