Acer AR385 F1 Specifications
Technical Specifications
Dimensions
438.4 mm (W) x 705 mm (D) x 88.1 mm (H) ( 17.3 x 27.8 x 3.5 inches)
(with bezel)
Form factor
2U rack optimized with cable arms included
Weight
Maximum
(approximate)
(All component slots and sockets
fully installed)
Minimum
(One HDD, power supply, and
processor installed)
BTU rating
Maximum
System inlet
Operating
temperature
Non-operating
Relative humidity
Operating
(non-condensing)
Non-operating
Acoustic noise
Listed are the declared A-weighted sound power levels (LWAd) and declared
average bystander position A-weighted sound pressure levels (LpAm) when the
product is operating in a 21° C ambient environment. Noise emissions were
measured in accordance with ISO 7779.
Idle
Operating
Emissions
FCC rating
classification
(EMC)
Normative standards
Rated Steady –state power
Power supply
Maximum Peak Power
BTU rating
39 kg (88.1 lbs)
28.5 kg (62.8 lbs)
3276 BTU/hr
10° - 35° C (50° - 95° F) at sea level with an
altitude derating of 1° C per 305 m (1.8° F per
1000 ft.) above sea level to a maximum of 3050 m
no direct sustained sunlight.
(10,000 ft.)
Maximum rate of change is 10°C/hr (18°F/hr).
The upper limit depends the type and number
of options installed. System performance may
be reduced if operating with a fan fault or
above 30°C (86°F).
-40° - 70° C (-40° - 158° F)
change is 20°C/hr (36°F/hr).
8 - 90 % relative humidity (Rh), 28° C (82.4° F)
maximum wet bulb temperature, non-condensing
5 - 95 % relative humidity (Rh), 38.7° C (101.7° F)
maximum wet bulb temperature, non-condensing
LWAd: 6.4 BA/ LpAm: 45.8 dBA
LWAd: 7.2 BA / LpAm: 53.6 dBA
Class A
EN55022, EN 61000-3-2, EN 61000-3-3, CISPR
22 Class A
720 W
728 W
2456.64 BTU/hr at 100 - 240 VAC
Maximum rate of
5