Plastic Tee Type Flow Sensor
Electrical Installation "Magnetic" sensors
The magnetic sensor has a custom wire connector that connects to the series 1400 monitor only. The cable
may be extended up to 100 feet from the sensor. If extension cables are needed they may be ordered from
Data Industrial.
Electrical Installation (FM Sensors)
The Series 200 Sensor is approved, as an entity, as Intrinsically Safe when installed in conformance with Data
Industrial installation drawings 06-480-001 or 06-480-002 (samples shown on Page 5) as specified on the blue
label identifying an intrinsically safe sensor.
Entity approval implies that only the sensor is approved as intrinsically safe. Unless power supplies, equipment,
and instruments connected to the sensor are each rated either explosion-proof or intrinsically safe, these
devices cannot be installed in a hazardous area. The referenced installation drawing shows such apparatus
located in a non-hazardous location. Proper interfacing between the hazardous and non-hazardous areas must
be provided. It is of absolute importance that this interface be constructed and that all wiring be performed by
qualified contractors. To ensure the Intrinsic Safety of the installation, the connection of the intrinsically safe
sensor to instruments and or power supplies must take place using an approved intrinsically safe barrier located
in a non-hazardous area. These barriers, listed below, are readily available from various suppliers.
Manufacturer:
Crouse-Hinds Spec 504
Measurement Technology Ltd.
R Stahl Intrinspak
4
Manual
Cable Length
Part #
5'
7101
10'
7108
20'
7102
50'
7109
Barrier:
Cat No. SB19140M0715
MTL 715+ 15 V
9001/01-158-150-10