DUROFIX RI60164-6 Produktinformation Handbuch - Seite 13
Blättern Sie online oder laden Sie pdf Produktinformation Handbuch für Schlagschrauber DUROFIX RI60164-6 herunter. DUROFIX RI60164-6 16 Seiten. Brushless impact wrench
Always follow the procedure below to install a socket.
1.
Insert a socket into the anvil. (see Fig. 3)
2.
Make sure the bit is fixed in the anvil while clicking on the ball of the anvil.
REMOVING SOCKETS
Always follow the procedure below to remove a socket.
Pull out the socket from the anvil directly. (see Fig. 3)
CAUTION
NOTE
Always check the direction of the rotation before use.
1.
After continuous use, allow the impact wrench to sit idle for 15 minutes before
replacing the battery. The temperature of the motor, switch, etc., will rise if the
work is started again immediately after the battery has been changed, eventually
resulting in burned-out.
2.
Place the point of the bolt in the socket. Keep the tool pointed straight at the bolt.
3.
Apply forward pressure to the tool to prevent the socket from slipping off the bolt.
4.
To start, turn impact wrench/driver on. Always check torque with a torque wrench.
The fastening torque can be affected by many factors including the following:
Voltage: Low voltage due to a nearly discharged battery will reduce the fastening
torque.
Socket Size: Failure to use the correct socket size will cause a reduction in fastening
torque.
Variable Speed Trigger Switch: Operating the tool at a reduced speed will reduce the
fastening torque.
1English1
Fig. 3
Always set switch (5) to off position when installing and
removing socket.
OPERATION
English
-13