Data-Linc Group DLM4100 Benutzerhandbuch - Seite 5

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Modem Data-Linc Group DLM4100 herunter. Data-Linc Group DLM4100 19 Seiten. Compact dial-up modem

AT Commands
A- Answer Command – ATA forces the modem to immediately go off-hook and begin transmitting the
answer tone sequence.
Bn- Select Communications Standard – ATBn selects the modulation scheme used for connections
below 2400 bits per second.
n=0 Selects CCITT standards
n=1 Selects Bell standards
D- Dial Command – Below are the characters accepted in a dialing command.
0-9, #,* = Dialing Digits
L = Re-dial last number
P = Pulse dial
T = Tone dial
S=n = Dial stored number
W = Wait for dial tone
^ = Toggles state of calling tone
, = Pause for the duration of S8
@ = Wait for silence
! = Switch hook flash
; = Return to the command state
En- Command Echo – ATEn determines whether commands will be echoed back to the host.
n=0 Do not echo commands
n=1 Enable command echo
Hn – Switch Hook Control – ATHn opens and closes the modem's hook switch.
n=0 Switch hook relay opens
n=1 Switch hook relay closes
Ln- Speaker Volume – ATLn Sets the amplitude of the modem's audio output
n=0 Lowest speaker volume
n=1 Low speaker volume
n=2 Speaker remains on
n=3 Speaker off during dialing, on until carrier
Mn- Speaker Activity – ATMn determines when the modem's audio output is active.
n=0 Speaker off
n=1 Speaker on until carrier received
n=2 Speaker remains on
n=3 Speaker off during dialing, on until carrier
P/N 161-09977-001B
DLM4100 User's Manual
4