3.4 RS-232 Interface
No.
1
2
3
4
5
6
7
8
3.5 Serial Communication Control
●
RS232 Communication Control
The camera is controlled via RS232. The RS232 serial port parameters are as follows:
Baud rate: 2400/4800/9600/38400 bit/s;
Starting Position: 1 bit
Data bit: 8 bits
Stop bit: 1 bit
Check digit: None
● RS485 Communication Control
Control camera via RS485, half-duplex mode:
Baud rate: 2400/4800/9600/38400 bit/s;
Starting position: 1 bit
Data bit: 8 bits
Stop bit: 1 bit
Check digit: None
●
List of protocols
For a detailed list of VISCA/Pelco-D/Pelco-P protocols, please check www.cave-tek.com.
Function
DTR
DSR
TXD
GND
RXD
GND
IR OUT
NC
4
The correspondence between the camera and
Windows DB-9 pin:
Camera
1.DTR
2.DSR
3.TXD
4.GND
5.RXD
6.GND
7.IR OUT
8.NC
The correspondence between the camera and
the Mini DIN pin:
Camera
1.DTR
2.DSR
3.TXD
4.GND
5.RXD
6.GND
7.IR OUT
8.NC
User Guide
Windows DB-9
1.CD
2.RXD
3.TXD
4.DTR
5.GND
6.DSR
7.RTS
8.CTS
9.RI
Mini DIN
1.DTR
2.DSR
3.TXD
4.GND
5.RXD
6.GND
7.NC
8.NC