Setting ventilation speed
Press SPEED button to choose the ventilation speed you need, high, medium or
low. The sign of high or low ventilation will light on at the same time.
Setting timer
1. Press TIMER button to set the operating hours you desired (1 to 24 hours, the
sign of timer will light on). When the set time has been reached, the machine
will turn off automatically. The display window will show the hour(s) you set as
you press TIMER button. If the timer button is not pressed, the unit will work
continuously.
2. By pressing the timer but without turning on the other functions, you can PRE-
SET the time for the machine to work. For example, if you press the timer to
'2', the unit will work automatically after 2 hours.

Sleep function

1. In cooling mode, by pressing the SLEEP button, the set temperature will
increase 1oC at the 1st hour, another 1ºC at the second hour, then keeps at
that temperature.
2. In sleep mode, the ventilation will keep at low speed. Re-press the SLEEP button,
the setting temperature and ventilation speed will return to the pre-selected one.
3. The unit will shut down automatically after the SLEEP function running for
12 hours.
4. Please note, the sleep function is not available while the machine is working
in ventilation, dehumidification or auto mode. Only available in Cooling or
Heating mode.
5. When the machine is in Sleep function, the Fan Speed would turn to be
LOW speed.
Dehumidify (DRY) mode
In dehumidify (DRY) mode, the temperature cannot be adjusted, the ventilation
will fix at low speed. When the unit is operating in Dehumidify ( DRY) mode,
humidity extracted from the air is collected in an internal tank. If the tank reaches
full, the compressor and motor cut out automatically. At the same time, the
"Water Full" indicator comes on. An alarm will also sound. When the tank is full,
drain the water as shown in the page about "DRAINAGE". You may also use the
unit without having to empty the tank so often by using "continuous drainage",
please also refer to the page about "DRAINAGE".