Cavity Sliders Solic CS005 Betriebshandbuch - Seite 5

Blättern Sie online oder laden Sie pdf Betriebshandbuch für Türöffnungssystem Cavity Sliders Solic CS005 herunter. Cavity Sliders Solic CS005 16 Seiten. Automatic sliding door operator, motor - m005 (hypoid gear type)

8*0.5 mm2
DOOR
M
CONTROLLER
2*0.5mm2
4. TRANSFORMER INPUT CONNECTIONS (Input • Output)
ACCESS
ADVANCED
PANEL SIDE
FEATURES SOCKET
ACTIVATION
(See Separate Instructions)
SWITCH
A B C D E
1 3
H G G G F
2 4
LOCK SWITCH
5 6
ACTIVATION SWITCH
+
1 RED
24VAC
2 BLACK
3 WHITE
SWITCH
4 BLUE
1. Activation Switch (2 supplied with unit)
Lead output wires of activation device such as sensor switch, button etc., to be
connected to this input plug in track. Two 5m 4-core wires will be supplied with the
correct terminal connection to plug into the input.
- The door opens and closes when signalled from the activation device.
2. Lock Switch – (If optional lock is attached)
Lead output wires of activation device such as sensor switch, button etc., to be
connected to this input plug in track. A single 5m 2-core wire will be supplied with
correct terminal connection to plug into the input.
- When the lock switch is turned ON the lock will engage
- Lock will automatically disable, and the door opens when the activation switch is
on. Lock will automatically re-engage when closed.
- When the Lock switch is turned OFF the door can be pushed open.
3. Safety Beams – (Optional upon order)
Safety beams can be applied to the auto door unit upon request. These will be
fitted/wired in position on the cavity and auto head prior to leaving the factory.
- Only during a closing movement, the door will open and stay open while the
beam lines are broken (When something is in/crossing the walkway).
- The beams are only active while the door is open/closing. When the door is fully
closed, breaking the beams will not open the door.
4. Advanced Features – (Optional upon order)
The following advanced features can be applied to the auto door unit upon request.
The wire loom - L003 will need to be ordered from CS FOR DOORS to be able to
wire/connect the activation devices to the controller:
OUTPUT 24VAC 0.5A
24V AC is supplied from this output for an auxiliary device requiring power.
- Terminal A and H on advanced input plug (A is line, H is neutral)
BREAKAWAY
When breakaway is active, power is cut to the motor and the door is operated as a
manual slider. Power is still connected to the controller and motor acts as a soft-
open/close device to avoid pinching fingers when operating the door by hand.
When the switch is turned off the door resumes normal operation.
- Connect activation device to Terminal C and G on advanced input plug.
SAFETY BEAM
CONTROLLER
11*0.5mm2
OTHER
SIDE
ACTIVATION
SWITCH
1 3
2 4
LOCK SWITCH
5 6
LOCK SWITCH
5 RED
LOCK
6 BLACK
INPUTS
15*0.5mm2
Lock SW1
Lock SW2
M005
POWER OUTLET
120 / 230VAC-3A
3*1mm2
M007
• Slides up and down to adjust heigh
of belt or to separate from drive ba
• Loosen front screws to adjust
F = Front. Must face
(visible) when instal
Belt Clamp
Bracket
Drive Bar
Front
Screws
(2)
Connector Bracket
Height Adjusting Screw
Remove these screws onl
need to take door out of p
5