Elsema G-2025 Handbuch - Seite 10
Blättern Sie online oder laden Sie pdf Handbuch für Empfänger Elsema G-2025 herunter. Elsema G-2025 14 Seiten. 4g receiver with relay output for opening sliding, swing gates, doors or switching devices

SMS confirmation of relay switching
This feature enables the 1
ON or OFF.
For relay ON you need the following command
PwdGONab#content#
o
For relay OFF you need the following command
PwdGOFFab#content#
o
Ab is the option for the 1
switching. Have a look at the table below:
A (First user)
Content is the SMS message which the user and the caller will receive.
st
E.g. If only the 1
command is needed
1234GON10#gate open#
st
E.g. If the 1
user and the caller both are required to receive SMS "gate closed" when the relay is OFF, the
following command is needed
1234GOFF11#gate closed#
If SMS is not required for any users when the relay is ON, the following command is needed.
PwdGON##
o
1234GON##
If SMS is not required for any users when the relay is OFF the following command is needed.
PwdGOFF##
o
1234GOFF##
www.elsema.com
st
user and the person making a call to get SMS confirmation of the relay switching
st
user and the caller to either receive or not to receive SMS confirmation of the relay
AB Option
B (Caller)
0
0
0
1
1
0
1
1
(0) means disable & (1) means enable
user is required to receive SMS "gate open" when the relay is ON, the following
SMS Confirmation to user
st
1
user
√
√
Page 10
ELSEMA
4G Receiver with relay output, G-2025
Caller
√
√