If a dedicated wire harness is not available, identify ground and 5V supply lines in the emulated sensor plug
and make a connection. Cut the ECU signal line wire and connect the yellow line on the sensor side and the
green line on the ECU side.
The STAG TUNING kit is supplied with +5V from the MAP sensor line. Do not connect an additional power
supply line. Install the kit away of heat sources and avoid water contact, e.g. when washing the engine!

3. Description of terminals

MAP sensor terminals
1- ground
(brown),
2- temperature
(red and black),
3- 5V power supply
(red),
4- signal
(yellow to sensor, green to ECU).
MAP sensor connector, typ A
AC S.A. All rights reserved. Any unauthorized copying, reproduction, publishing, dissemination, disclosing or other use of information presented herein, in whole or as part, particularly photographs,
 