Model Description:

Reading Performance:

Version
0XX0
75 mm (3 in) - 340 mm (13.4 in) on 0.35 mm (14 mils) codes
1XX0
100 mm (3.9 in) - 440 mm (17.3 in) on 0.50 mm (20 mils) codes
2XX0
190 mm (7.5 in) - 600 mm (23.6 in) on 0.50 mm (20 mils) codes

Technical Features:

ELECTRICAL FEATURES
Power Supply
Power Consumption
Main Serial Interface
Auxiliary Interface
Baudrates
Inputs
External Trigger
Voltage max.
Current Consumption 25 mA
max.
Outputs
)
OUT1, OUT2
V
max.
CE
Collector Current
max.
V
Saturation
CE
Power Dissipation
max.
OPTICAL FEATURES
Light Source
Wavelength
Safety Class
USER INTERFACE
LED Indicators
PHYSICAL FEATURES
Dimensions
Weight
2
DS2400A - X X X 0
Reading Range
Communication Interface
0 = Short range
2 = RS232/RS485 main + RS232 aux
1 = Medium range
2 = Long range
Reading Distance
10 –30 Vdc
5 W maximum
Programmable:
RS232;
RS485 Full-Duplex/Half-
Duplex;
RS232
150 to 115200
(optocoupled NPN or PNP)
30 Vdc
(optocoupled)
40 Vdc
40 mA continuous;
130 mA pulsed
1V at 10 mA max.
90 mW at 40 °C
(Ambient temp.)
semiconductor laser diode
In the range 630 to 680 nm
Class 2 - EN 60825-1; CDRH
Laser ON, Good Read,
External Trigger,
Data TX / Power ON
68x83.6x34 mm
(2.7x3.29x1.3 in)
330 g.
(11.64 oz)
Optic Version
0 = Linear
1 = Raster
Max Code Resolution
SOFTWARE FEATURES
Readable Codes
*
EAN/UPC
(including Add-on 2 and Add-on 5)
Code 39
*
2/5 Interleaved
*
Code 128
*
EAN 128
*
Codabar
*
Code 93
*
* = ACB readable
ISBT 128
Pharmacode
Headers and
Up to four header and four
Terminators
terminator characters
Operating Modes
On-Line, Automatic,
Serial-On-Line, Test
Configuration Modes Through menus using:
WinHost utility
Host Mode (commands from
one of the serial ports)
Code Selection
Up to six different codes
during one reading phase
Decoding Safety
Can enable multiple good
reads of the same code
Special Functions
ACB (Advanced Code Builder)
Motor Off
Parameter Storage
Non-volatile internal EEPROM
ENVIRONMENTAL FEATURES
Operating
0° to +40 °C (+32° to +104 °F)
Temperature
Storage
-20° to +70 °C (-4° to +158 °F)
Temperature
Humidity max
90% non condensing
Vibration Resistance 14 mm @ 2 to 10 Hz;
IEC 68-2-6 test FC
1.5 mm @ 13 to 55 Hz;
2 G @ 70 to 200 Hz;
2 hours on each axis
Shock Resistance
30 G;
IEC 68-2-27 test EA
11 ms; 3 shocks on each axis
Protection Class
IP65
DS2400A QUICK GUIDE
Speed
mm (mils)
scans/s
0.20 (8)
600 to 1000
0.25 (10)
600 to 1000
0.35 (14)
600 to 1000