PRS300 BUS
The PRS300
using the correct charge line (which can be selected with the switch placed inside the regulator):
lead-gel, lead-acid, AGM and lithium batteries (with integrated electronics).
The charging procedure occurs in three steps:
Step 1:
Battery charge
voltage is reached.
NOTE: the end of charge voltage is reached only if
Step 2:
Battery charg completion
Step 3:
Maintenance
The cycle starts again when the battery voltage is lower than 13Vd.c., such as in the case of
equipment turning on.
Note:
an
A desulfation function is automatically activated when required by the battery.
Position the selector on the end of charge voltage recommended by the battery manufacturer.
Generally, the selector should be set on position "A" for lead-acid batteries, position "B" for lead-gel
batteries, and position "C" for AGM and lithium batteries.
STEP 1 - END-OF-CHARGE VOLTAGE
STEP 2 - DURATION CHARGING COMPLETION
STEP 3 - MAINTENANCE VOLTAGE
- The
device
to other equipment which can damage
- The regulator must be exclusively used with the types of batteries listed above The kind of battery
to charge shall be set on the solar regulator internal board using the
8); the wrong setting of the battery to charge may damage the battery itself!
Note: the PR
batteries without integrated electronics or other kinds of rechargeable or non rechargeable
batteries.
- The regulator is not suitable for external use.
- Install the regulator in an appropriate dry and ventilated housing; make sure there is a minimum
distance of 300mm from the front and 100mm from the sides to the surrounding surfaces.
- Do not cover
- The
device
equipment near the instrument does not hamper the correct air flow and prevent the necessary
instrument cooling.
- Use cables with
recommended).
GB
- Protect the cable from any possible damage.
- Protect the 12V battery line using a suitable fuse to be placed close to the battery.
4
solar
charge regulator can automatically charge the following 12Vd.c. battery types
with
the maximum current of the photovoltaic module
- -
e
at
a
constant voltage.
uneven exposure to sunlight may lead to varying charging times.
shall be used for the regulation of
S300 r
egulator is not suitable for the charging of nickel/cadmium batteries, lithium
the
air intakes on the lid.
produces heat during
an
appropriate section ( 6mm²
s
at the end-of-charge voltage with
Position "A"
14.1 V
1h
13.5 V
12V
photovoltaic modules charging only. Connection
its
correct operation may result in warranty void.
its
normal operation. Make sure that the installation of other
a
section for each
, until the end of charge
the
batteries are efficient.
a gradual current reduction
Position "B"
14.3 V
4h
13.8 V
.
apposite
selector (see page
photovoltaic module
- -
.
Position "C"
14.7 V
2h
13.8 V
is