Dataprobe iBoot Handbuch - Seite 13
Blättern Sie online oder laden Sie pdf Handbuch für Schalter Dataprobe iBoot herunter. Dataprobe iBoot 20 Seiten. Web enabled remote power control
Auch für Dataprobe iBoot: Gebrauchsanweisung (16 seiten)
iBoot Ver 1.5
Page 13
cycle, click on either Power On or Power Off buttons. iBoot will
assume the status selected.
Use the Refresh link to obtain the latest status of iBoot. Using
your browser's refresh button can lead to inadvertent power
switching.
If the Auto-Ping Feature is in
use then the page will also
display the current status, OK
or Triggered, with a counter of
how many times the Auto-Ping was triggered. If connecting with
the Setup Password, a reset button for the counter is provided.
When you are finished
with iBoot, click on
Logout. A confirmation
page will be displayed. If
you close your browser
window without first
clicking Logout, there will
be a two minute delay
before you can re-
access iBoot.
iBoot uses an inactivity timer for security. When there is no
activity for 2 minutes, the user is logged out and the password
will need to be entered again for access. This is to prevent
accidental lockout by leaving the user logged in.
The Auto-Ping status will indicate whether this feature is
Enabled, Disabled, or Triggered. It will display Triggered to
indicate that it has not received a response to the ping, and has
performed its programmed function. Once the ping returns, the
status will return to Enabled.
To access the Setup page, the Setup Password must be used
for the initial login. The factory default for the Setup Password,
as well as the operation password is PASS. Both passwords
can be changed in Setup.