Regular servicing will help to extend the life
of the water heater, and keep it operating
safely and efficiently.
Your water heater warranty is not
conditional on completing the regular
servicing recommended in this manual.
The conditions applying to your water
heater warranty are set out on page 9 of
this manual.
Six Month Service:
This service may be carried out by the
owner.
1.
Stand clear of the Pressure &
Temperature Relief (PTR) Valve drain
pipe outlet.
2.
Open the PTR Valve for approximately
10 seconds by lifting the easing lever
on the valve. Confirm water discharges
to waste through the drain pipe.
3.
Lower the easing lever gently and
check it closes correctly.
4.
Repeat the above process for the
expansion control valve (if installed).
Other than this, personally inspecting or
servicing any part of the water heater is not
recommended.
H0421
0421
Rev. Q
Owner's Manual – Proflo Electric Storage Water Heaters

System Maintenance

Five Year Service:
This service should only be carried out by
a licensed tradesperson. We recommend
your local Dux Service Agent.
In locations where the water has Total
Dissolved Solids (TDS) exceeding
600 mg/L, this service is recommended
every 3 years.
This service should include the following:
Replace the PTR Valve.
Replace the anode.
Inspect and flush the expansion
control valve (if installed).
Drain and flush the water heater.
Inspect the condition of the electrical
conduit and the water heater electrical
cover. Replace any damaged
components.
Replacement parts are available from your
local Dux supplier.
7