Datasensor S62-PL-5-B01-NN Gebrauchsanweisung - Seite 3

Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Zubehör Datasensor S62-PL-5-B01-NN herunter. Datasensor S62-PL-5-B01-NN 4 Seiten.

S62-PL...B Laser
Polarised retroreflex
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (yellow)
The yellow LED ON indicates the following output status: N.O.
closed and N.C. open.
POWER ON LED (green)
The green LED ON indicates the sensor powering status and
laser emission presence.
SENSITIVITY TRIMMER (ADJ.)
Monoturn trimmer that adjusts the sensitivity and thus the
sensor operating distance.
Please refer to "SETTING" paragraph for the correct use
procedure.
WARNING: the maximum mechanical trimmer rotation is
equal to 240°. Do not apply excessive torque over the
maximum and minimum positions.
INSTALLATION
The sensor can be positioned by
means of the three housing's
holes using two screws (M4x25
or longer, 1.5 Nm maximum
tightening torque) with washers.
Various orientable fixing brackets
to ease the sensor positioning
are available (please refer to the accessories listed in the
general catalogue).The operating distance is measured from
the front surface of the sensor optics.
The M12 connector can be oriented at two different positions
using the specific fastening spring and rotating the block to
180°.
CONNESSIONS
M12 connector
TECHNICAL DATA
Power supply:
Ripple:
Consumption
(output current excluded):
Outputs:
PNP or NPN N.O. / N.C.; 30 Vdc max. (short-circuit protection)
Output current:
Output saturation voltage:
Response time:
Switching frequency:
Emission type:
RED LASER (λ = 645...665 nm): Class 2 EN 60825-1 (1994), Class II CDRH 21
Operating distance (typical values):
Min. detectable object dimension:
Indicators:
Setting:
Functioning temperature:
Storage temperature:
Dielectric strength:
Insulating resistance:
Ambient light rejection:
Vibrations:
0.5 mm amplitude, 10 ... 55 Hz frequency, for every axis (EN60068-2-6)
Shock resistance:
Housing material:
Lens material:
Mechanical protection:
Connections:
Weight:
Alignment:
- Position the sensor and reflector aligned on opposite sides at the
desired distance.
- Turn
to
maximum
the
sensitivity adjustment
(clockwise).
- Determine the powering on and powering off points of the yellow LED
(OUT) by moving vertically and horizontally the sensor and mount the
sensor in the middle of the points found.
Control:
- Enter laterally the object inside the
operating field and control that the
yellow LED turns on.
- Remove the object and check that
the yellow LED turns off immediately
PERFORMANCES
TAB.1: Operating distances (m)
REFLECTOR
R1
R2
R6
R7 /R20
0.3 ... 16
0.3 ... 20
0.4 ... 22
0.3 ... 22
Note: The use of the RT 3970 reflecting tape is not suggested.
10 ... 30 Vcc
2 Vpp max.
30 mA max
100 mA max (overload and overvoltage protection)
≤ 2 V
200 µs
2.5 kHz
CFR PART 1040.10
Pulsed emission: pot. max ≤ 5 mW; pulse duration = 5 µs;
frequency max = 32 KHz
refer to TAB.1
0.5 mm at 0.5m (minimum spot)
OUTPUT LED (YELLOW) / POWER ON LED (GREEN)
Monoturn sensitivity adjustment trimmer
-10 ... 55 °C
-20 ... 70 °C
500 Vac 1 min., between electronics and housing
>20 MΩ 500 Vdc, between electronics and housing
according to EN 60947-5-2
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
ABS
PMMA window, polycarbonate lenses
IP67
M12 4-pole connector
40 g. max.
SETTING
trimmer
(ADJ.)
spot diameter (mm)
R8
0.2 ... 2
distance (mm)
DIMENSIONS
50
18
42
4.7
RECEIVER
EMITTER
11
6
14
M12
Ø15
25
SENSITIVITY TRIMMER
6.18
mm
10.7
POWER ON LED
OUTPUT LED
SAFETY PRECAUTIONS
All the electric and mechanical
safety regulations have to be
respected
during
sensor
functioning.
The sensor has to be protected
against mechanical damage.
Apply the labels supplied in a
visible position near the laser emission beam.
Do not stare directly into the laser beam!
Do not point the laser beam towards people!
Eye irradiation superior to 0.25 seconds is dangerous.
Please refer to the Class 2 Standard (EN60825-1).
These sensors can not be used for safety applications!
EX-II-3D T6
T6 (<85°C)
Temperature class:
Max. Power consumption: 800 mW at 30 Vdc
Max. Internal capacitance: 100 nF
Internal inductance:
negligible
DECLARATION OF CONFORMITY
We DATASENSOR S.p.A. declare under our sole responsibility that
these products are conform to the 2004/108/CE, 2006/95/CE Directives
and successive amendments.
WARRANTY
DATASENSOR S.p.A. warrants its products to be free from defects.
DATASENSOR S.p.A. will repair or replace, free of charge, any product
found to be defective during the warranty period of 36 months from the
manufacturing date.
This warranty does not cover damage or liability deriving from the
improper application of DATASENSOR products.
DATASENSOR S.p.A. Via Lavino 265
40050 Monte S. Pietro - Bologna - Italy
Tel: +39 051 6765611
Fax: +39 051 6759324
http://www.datasensor.com
DATASENSOR S.p.A. cares for the environment: 100% recycled
paper.
DATASENSOR S.p.A. reserves the right to make modifications
and improvements without prior notification.
826003251 Rev.B