OVERSPEEDING
Do not operate machine at over 3200rpm (motor speed). Over speeding can cause serious pump
damage.
EXCESSIVE BYPASS
Do not run on excessive by-pass. Switch machine off within two minutes of ceasing operation as
excessive by-pass can cause heat build up in pump and subsequent damage. Excessive bypass running
voids warranty.
HIGH PRESSURE SETTING
The high pressure pump is factory set to operate at its rated pressure. DO NOT ADJUST. Tampering
with the pressure regulator will void warranty and can be DANGEROUS.
PRESSURE CLEANER DAILY CHECK LIST
Check pump oil level
Check all high pressure components for leaks:
gun/lance
HP hose
all fittings
Check water filter and clean if necessary
Check unloader and thermal dump for leaks
THREE MONTHLY REGULAR SERVICE
All professional machines need to be thoroughly serviced every three months.
Change pump oil
Check filter for foreign debris
Check unloader and thermal dump for leaks
Check all HP components for leaks: Gun/lance, HP hose and all fittings
To maintain the Bertolini pump warranty (four years from date of purchase), the pump must be serviced by an
authorised service agent every six months. Contact Aussie for your nearest agent.
LOOK AFTER YOUR MACHINE AND IT WILL LOOK AFTER YOU!
Aussie HP Accessories ... making light work of cleaning chores
WEAR PROTECTIVE GOGGLES & CLOTHING!
WARNING
SIX MONTHLY REGULAR SERVICE
Australian Pump Industries Pty Ltd
7 Gladstone Road, Castle Hill NSW 2154
Ph: (02) 8865 3500 Fax: (02) 9894 4240
www.aussiepumps.com.au [email protected]