Issue
The unit is not working
The unit starts and stops
frequently
Poor heating
performance
Indicator lamps continue
flashing
Error code appears in
the window display of
indoor unit:
• E0, E1, E2...
• P1, P2, P3...
• F1, F2, F3...
NOTE: If your problem persists after performing the checks and diagnostics above, turn off your
unit immediately and contact an authorized service center.
Page 18
Possible Causes
Power failure
The power is turned off
The fuse is burned out
Remote control batteries are
exhausted
The Unit's 3-minute protection has
been activated
Timer is activated
There's too much or too little
refrigerant in the system
Incompressible gas or moisture
has entered the system.
The compressor is broken
The voltage is too high or too low
The outdoor temperature is
extremely low
Cold air is entering through doors
and windows
Low refrigerant due to leak or long-
term use
The unit may stop operation or continue to run safely. If the indicator lamps continue
to flash or error codes appear, wait for about 10 minutes. The problem may resolve
itself.
If not, disconnect the power, and then connect it again. Turn the unit on.
If the problem persists, disconnect the power and contact your nearest customer
service center.
Solution
Wait for the power to be restored
Turn on the power
Replace the fuse
Replace batteries
Wait three minutes after restarting the unit
Turn timer off
Check for leaks and recharge the system with
refrigerant.
Evacuate and recharge the
system with refrigerant
Replace the compressor
Install a manostat to regulate the voltage
Use auxiliary heating device
Make sure that all doors and windows are closed
during use
Check for leaks, re-seal if necessary and top off
refrigerant