AUSSIE BLASTER PRESSURE TESTING & SETTING
AUSSIE PRESSURE CLEANER TEST SET
Everybody knows that professional pressure cleaners
occasionally need to have their pressure tested and sometimes
reset. Doing this efficiently, and in line with our professional
recommendations is not easy unless you have the right
equipment.
Checking pressure regularly will tell you if nozzles are worn, if the
pressure regulator is worn, if there are leaks in the system, if the
valves are sticking and signal other problems that can manifest
themselves in low pressure operation.
The Aussie Test Set (Part number ATESTSET) will solve those
problems. Consisting of a convenient brass T with M22 quick
coupler and 6,000 psi pressure gauge you can check to make
sure everything is operating as it should. Detailed instructions are
included with each kit.
PRESSURE TESTING INSTRUCTIONS .... 2,000 PSI PETROL ENGINE BLASTERS
1.
Connect machine to mains pressure water supply,
ensuring that water is passing freely through the
pump at the correct flow rate for specified pump by
holding the gun trigger open.
2.
Ensure that nozzle fitted in lance is the correct size
(BB100 nozzle should be 035). Replace nozzle if
worn or damaged. Check there are no leaks in the
hose or high pressure connections.
3.
Check oil level in pump, gearbox and engine before further
testing.
4.
Fit pressure gauge kit between high pressure outlet of pump
and high pressure hose.
5.
Turn on engine with the trigger on the gun pressed. Check
the engine rpm is set to 3200. Adjust if necessary. Let the
engine run for a few minutes to warm up.
Check the pressure on the gauge (BB100 should read 2,000
6.
psi) when blaster is operating. If adjustment is required refer
to next instructions .
Aussie BB Hire Series ... Operation & Maintenance Manual
Aussie Pumps
Pressure gauge kit fitted between pump high
pressure outlet and high pressure hose
11