DVS G3 Montageanleitung
Resetting the system clock (where applicable), the filter reminder or the filter warning light.
DVS G4
Models distinguished by a small, coloured LED screen.
You will need to reset the filter reminder timer. Press the MENU button then the up and down arrows to select UTILITES,
then select Filter Reset, Press OK and follow the screen prompts.
DVS G3
Models distinguished by a square grey, LCD touch screen.
First, you will need to reset the clock. Touch the screen and then follow the prompts.
To reset the filter reminder timer. Press MENU - MORE – MORE – FILTER – Press UP and DOWN arrow until you reach the
required months (12). Note, it automatically resets to 12 months.
DVS 1 or 5
Models distinguished by the mid or light Grey key pad. These models also include:
Summer / winter selection button on the bottom right side of the control panel.
Warm / cold roof temp indication on the bottom left side.
There may also be an Air warmer button and/or an Auto summer vent button. However these were optio nal extra
s and may not be present.
To reset when the filter light is flashing:
Press and hold down the summer / winter selection button, the air change lights will flick up to 6 lights then disappear, the
filter light will go off.
If filter light has stopped flashing:
Press and hold summer / winter select button. The summer / winter lights will flash.
Use up arrow to add 6 complete lights on air change scale (6 lights = 12 months).
DVS 5E
Models distinguished by:
This model has no Warm/Cold indicator. Mid or light Blue coloured key pad.
NOTE: Some DVS5E models do not have a filter reset indicator or any lights, so, no reset is required.
There are two versions:
(Take off the switch cover and look for the V number on the sticker to one side)
V 1.2.4 (Typically up to 2007)
Press and release the up and down arrows at the same time, the summer / winter light will start flashing.
Press the summer / winter select button 2 times. Use the up arrow until you see 6 complete lights showing on the air
change indicator (6 lights = 12 months). Press the summer / winter select button once more.
The summer / winter lights will stop flashing and the filter light will disappear.
V 1.2.5 (Typically 2007 onwards)
Press and hold summer / winter selection button to reset, this is the same as the DVS1/5 models explained above.
DVS Air Transfer (ATS)
To reset the filter light, press POWER and SELECT buttons together. This will automatically reset the filter time out period to
12 months. If the filter light is not flashing, pressing the two buttons together will take the unit into filter time out dis play
mode with both the HEAT and COOL lights flashing. Time until the filter is due for changing will be displayed as a bar graph
starting from the green LED upwards. Each full brightness is two months so 8 LEDS is 16 months. We recommend a
maximum of 12 months, or 6 full LED's. To exit the display mode press the two buttons again.