When the container is removed, a negative value is shown on the display. If the scale has
been tared before removing the container, this value will be the gross weight of the container
plus all products that have been removed. "ZERO" appears on the display.
6.3

Determining the weight

To determine the weight, first possibly tare the container as described above.
Then place the items to be weighed on the weighing surface. The display will show the
applied weight including the selected unit of weight.
6.4

Weighing in percent

The scale provides for weighing in percent. The reference quantity is given as 100%. Any
additional weight placed on the scale will be displayed as a percentage of the reference
quantity.
Place the reference weight on the weighing surface and press the % button as soon as
STABLE appears on the display.
The reference weight is now displayed as 100.00%.
Now place additional weight on the weighing surface or remove some items from it: the
display will show the applied weight in % of the reference weight.
Press the % button to return to the weighing mode.
6.5

Piece counting

6.5.1

Method 1: Unknown reference weight

First possibly tare the empty container as described above and leave it on the weighing
surface.
Press the SMPL button to start counting pieces.
Place a certain number of items to be weighed on the weighing surface. You must know the
exact number. Enter this number using the numeric keypad.
Press the SMPL button again.
If additional weight is now placed on the weighing surface, the display will show the quantity
corrected accord-ingly.
Press the MODE button to switch the display between the counted quantity, unit weight, total
weight and again the counted quantity.
Press the SMPL button to switch the scale back to weighing mode.
6.5.2

Method 2: Known reference weight

First tare the empty container as described above and leave it on the weighing surface.
You can enter a known reference weight using the numeric keypad by pressing the U.WT.
button.
Confirm the value by pressing the U.WT. button again.
Now place the weight to be counted on the weighing surface and the display will show the
number of applied pieces.
Press the MODE button to switch the display between the counted quantity, unit weight and
total weight.
Press the SMPL button to switch the scale back to weighing mode.