5 Operating instructions
5.1 Standard operation
No further settings are required for standard operation once the control is switched on.
An uninterrupted operation only requires the re-filling of the bowl.
The bulk material must be filled into the middle of the conveyor
bowl. Otherwise the orientation system might be damaged or the
required capacity might not be achieved as falling parts can get
jammed in the orientation system.
Under certain circumstances an inadmissible noise level may oc-
cur (e.g. when opening the cover of the noise protection hood for
filling in parts).
Required behaviour:
Wear ear protection when working at critical sound levels
Settings for the specific device
5.2
The BF is a spring and mass vibration system that operates on the basis of its resonance
properties. All basic devices are set by the manufacturer to the mass moment of inertia
and weight values specified in section 3.3. If you comply with these values and toleranc-
es, there will be no need to adjust the BF.
However, if you fail to comply with these values, the inherent frequency of the BF will
have to be adjusted accordingly. Once the assembled feeder bowl has been mounted,
the inherent frequency of the drive unit must be tuned to the feeder bowl. The bowl feed-
er must always be adjusted 'sub- critically', in other words, the inherent frequency
must be approximately 5% above the exciter frequency. For a 100 Hz feeder this trans-
lates to an inherent frequency of around 104 Hz (6000 vibrations per minute), for a 120
Hz feeder to one of around 126 Hz (7200 vibrations per minute).
The fully set-up feeder bowl must be bolted to the basic device to allow the drive unit to
be tuned. Proceed as follows to tune the drive unit to the specific application:
1. Unscrew the cover from the BF and mount the feeder bowl on to the drive unit.
2. Place a part into the feeder bowl and use the control unit to set a low transport
speed.
3. Slowly loosen the lower mounting screw at one of the three spring assemblies on
the bowl side and watch the transport speed of the part inside the bowl.
4. If the transport speed increases initially at first and then decreases again as the
screw is loosened further, the drive unit is correctly tuned and the inherent fre-
quency is slightly above the exciter frequency.
Page 14
CAUTION
CAUTION
2014-11-10
Release: 4.3