If the Beaks of the Interior Assembly are
extended, use the Lever to retract them.
Remove the Handle Screws and lift the Interior
Handle off the Interior Base, place them aside.
Place the Exterior Assembly onto the exterior
face of the door stile. Rotate the protruding
Spindle into a vertical position.
While placing the Interior Base onto the interior
face of the door stile, note the following:
- Allow the protruding Spindle to enter the
receiving slot on the underside of the Interior Base.
- Locate the bosses on the underside of the
Interior Base into the holes in the door stile.
Pass the correct length Fixing Screws through
the Interior Base and screw firmly into the
Exterior Assembly.
NOTE: DO NOT OVER TIGHTEN FIXING SCREWS
To install a Keyed Cylinder into the Interior
Assembly, remove and discard the Cylinder Plug
from the underside of the Interior Pull.
Install the Keyed Cylinder into the Interior Pull
as shown in Figure G.
Fit Interior Pull
Place the Interior Pull over the Interior Base.
It may be necessary to rotate the Lever to find its
correct orientation. Refit the two Handle Screws.
Depress the Plunger and test the lock operation
by operating the Lever and Cylinder Key(s)
if applicable.
NOTE: Ensure the Beaks are in the retracted
position before closing the door.
To fix the Catch Assembly to the front of the jamb, reverse the Adjustment
Screws from their fully 'screwed-in' position three (3) full turns with the
3.0mm Hex Key. Reverse the Catch Plug Grub Screws with the 2.0mm
Hex Key and remove the Catch Plugs using a small screwdriver.
Close the door and position the Catch Assembly on the jamb opposite
the lock with a 1 to 2mm gap between the lock and Catch Assembly.
Mark the centre of the 'front fix' slots and drill the jamb with a 3.5mm drill.
or
'Front Fix' Catch Screw (3/8")
'Face Fix' Catch Screw (1")
Use the two 'Front Fix' Catch Screws provided to fit the Catch Assembly
lightly to the jamb. Gently close the door and operate the Lever to test
the Beak engagement. Move the Catch Assembly up and down and
adjust the Catch Plate in and out to achieve the best fit.
NOTE: If required use packers provided to align catch plate
assembly with interior handle assembly.
Tighten the 'Front Fix' Catch Screws, refit the Catch Plugs and tighten
the Catch Plug Grub Screws. Be careful not to over tighten these screws.
To fix the Catch Assembly to the face of the reveal, leave the
Catch Plugs in place, mark through the 'face fix' slots, and use the
'Face Fix' Catch Screws instead.
Interior Base
Figure G
Keyed Cylinder
Cylinder Plug
Interior 'D' Pull
OR
Fixing
Screw
Handle Screw
Plunger
Exterior
Spacer
SPACERS
Some applications require spacers between
Interior
the door and lock as shown.
Spacer
Door Jamb
Catch Assembly
Front Fix
Slot
Catch Plate
Face Fix Slot
Adjustment
Screw
'Front Fix'
Catch Screw
Catch
Plug
Catch Plug
Grub Screw
CARE & MAINTENANCE
Beak
Installation
The product must be installed according to the instructions included in the product packaging and the
door should be apertured according to the door "cut-out" dimensions and tolerances shown.
Interior
Prior to fitting ensure that:
Slim Pull
Doors stored on site are stored in a clean dry area free from cement, lime, paint, acid etc.
During fitting of the lock ensure that :
No metal swarf or other contaminants enter the lock body.
The fixing screws do not damage the product finish.
After installation of the door ensure that:
The door is correctly adjusted with the correct clearances.
The lock engages the catch plate correctly.
The door is protected from building fall-out such as wet plaster, mortar, and paint.
If the door becomes contaminated:
Do not paint the lock body or faceplate.
Remove wet plaster, cement, mortar and other droppings immediately, using clean water
and a sponge or rag, to avoid permanent staining or scratching of the product finish. If
removal is delayed and scraping becomes necessary the surface finish may suffer.
Maintenance
Annually inspect the door to confirm that the door operates with the correct clearances, closes and
opens without obstruction. Confirm that the lock beaks engage easily with the catch plate when the
door is closed and the lever or key is turned - adjust the door if necessary.
Annually check that when the door is closed, the lock can be locked by key and by the lever.
NB : The lock assembly has been lubricated for life, and should not be disassembled by the user.
Cleaning Powder Coatings
Every six months, powder coated surfaces should be cleaned to protect the finish. However, in areas
where pollutants are more prevalent, especially in coastal or industrial regions, cleaning should be
Lever
Lever
carried out every two to three months.
To clean the powder coated surface:
1. Carefully remove any loose deposits with a wet sponge.
2. Use a soft brush (non abrasive) or cloth and a mild household detergent solution to
remove dust, salt and other deposits. Do not use steel wool, scrapers, scouring liquids or
powders to remove deposits as these permanently scratch the coating surface.
3. Rinse off with clean fresh water.
Cleaning Chrome, Satin Chrome, Gold and Brass Finishes
Plated finishes are susceptible to tarnishing if they come into contact with moisture, wet paint, or water
vapour. All plated finishes should be coated with a non-abrasive furniture or car wax immediately after
installation. Plated finishes should be regularly wiped with a non-abrasive furniture or car wax, taking
care not to scratch any protective finishes that are employed to protect the surface and prevent
tarnishing.
MAINTENANCE LOG
In order to protect your warranty, record all maintenance activity in the following log:
Address of Building :
Name of Door :
Date
Activity
In te ri
o r D o
e n te rs
o r
h e re
Figure H
Austral Lock
31 - 33 Alfred Street
Blackburn
VIC 3130 Australia
Signed
ph 13 14 18
fax 13 18 14
www.ausloc.com
A Division of
GAINSBOROUGH
Hardware Industries