CookTek MagnaWave MCD3500 Benutzerhandbuch - Seite 9

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Kochfeld CookTek MagnaWave MCD3500 herunter. CookTek MagnaWave MCD3500 10 Seiten. Cooktek magnawave cooktops
Auch für CookTek MagnaWave MCD3500: Benutzerhandbuch Installation und Betrieb (11 seiten), Installations- und Benutzerhandbuch (10 seiten), Benutzerhandbuch und Installationsanleitung (6 seiten)

11
In the event of a possible malfunction, your CookTek cooktop will display and Error
Code on the LED display and the unit will beep the numer of times indicated by the
error. Please consult the following table when encountering an Error code. To
reset the error conditions, remove the pan from the unit and press the POWER
button or unplug the unit.
Error Error Description Potential Cause
RTD (temperature
1
sensor) is
RTD sensor has shorted
malfunctioning
RTD (temperature
Glass surface is too hot
2
sensor) temperature
or RTD sensor has
is too high.
broken.
Possible mechanical
3
Current is too high
damage to coil or foreign
object on cooktop.
Fan is broken, bad
Electronics are
4
ventilation, ambient
overheating
temperature too hot.
Something else is on the
same circuit. Line
voltage fluctuations at
Input line (from
end or beginning of work
6
power outlet) voltage
day. (Voltage > 132VAC
too high
for 120V model or
>264VAC for 240V
model)
7
Harware failure
Inverter I/O problem
Bad AC source, board
8
Zero cross error
component failure
16
System error
CPU I/O problem

WARRANTY STATEMENT

All commercial cooking and holding equipment manufactured by CookTek is
warranted against defects in materials and workmanship for a period of three years
from the date of shipment from CookTek's factory. All non-electrical equipment
such as pans, bags, and pellet assemblies are warranted against defects in
materials and workmanship for a period of 90 days from the date of shipment from
CookTek's factory.

ERROR CODES

Action Required
Reconnect or replace RTD.
Service may be required.
Remove any pans from cooktop
surface and let unit cool. Then
turn unit off, then on. If problem
was temperature related, the
unit will return to normal
operation. Otherwise, service is
required.
Try different cookware. Service
may be required.
Check airflow. Clear air vents.
Listen for fan operation.
To reset, unplug unit, wait 5
seconds, and plug in again. If
problem persists, have an
electrician monitor the line
voltage.
To reset, unplug unit, wait 5
seconds, and plug in again.
Service may be required.
Turn unit off, then on. Plug unit
into outlet on different circuit
breaker. If problem persists,
service is required on device.
To reset, unplug unit, wait 5
seconds, and plug in again.
(continued...)
Manual Universal 100336_A USINTL
8