STANDBY ENERGY CONSUMPTION
If no water is used for a long time after the end of the water heater's heating interval, the water in the tank
will cool down slowly but continuously due to losses at the unit's surface.
The speed of this cooling process depends on the type of device, its size, the thickness and the quality
of the tank insulation.
This behaviour is measured during a 24-hour period at a storage water temperature of 65°C, considering
the energy input in kWh that is necessary to keep the water temperature constant during this period.
Nominal content in litres
Standby energy consumption kWh/24h EKL
Standby energy consumption kWh/24h EKR
OPERATION
All operating elements required for the operation of the electric storage tank EKR (button to adjust the
temperature controller) and monitoring elements (operation indicator lamp and thermometer) are included
in a control panel on the front wall of the device.
Wall-mounted storage tank EKL do not have an operation indicator lamp and the button to adjust the
temperature controller of the horizontal storage tank is located on the front (connection side).
This tank can be used by children eight years old and older as well as by persons with reduced physical,
sensory or mental capabilities or who lack experience and knowledge if they are supervised or if they have
been trained with regard to the safe use of the tank and understand the resulting risks. Children may not
play with the tank or its packaging. Cleaning and user maintenance may not be performed by children
without supervision.
TEMPERATURE SETTING
As a setting aid, the adjusting knob of the electric heater's temperature controller has 4 main stages,
namely:
up to 30 °C
approx. 40 °C Hand warm tank water
approx. 65 °C Moderately hot tank water
approx. 85 °C hot tank water
Caution:
The adjusting knob at the left limit stop does not result in an off position or shutdown of the device heating.
The water may still have a temperature of 30 °C when operated in the frost protection position.
The temperature controller should not be set to a higher position than (approx. 65 °C) when operated
using day current. This position is recommended to rule out unintentiona scalding by excessively hot
water. The device operates particularly economically at this setting. The heat losses are minor and the
formation of boiler scale is largely avoided. Low standby energy consumption.
Due to the hysteresis of the temperature controller (± 7 K) and possible radiation losses (cooling of the
pipeline), the temperature specifications are subject to an accuracy of ± 10 K.
Frost protection for the tank
80
100
120
150
1,20 1,25 1,30 1,50 1,70
0,80 0,85 0,97
6
200
Id.Nr.: 228843-16