Austria Email EKL 150 Betriebs- und Wartungsanleitung - Seite 15

Blättern Sie online oder laden Sie pdf Betriebs- und Wartungsanleitung für Warmwasserbereiter Austria Email EKL 150 herunter. Austria Email EKL 150 20 Seiten. Pressure resistant electric water heater with control panel of the series

Reconnection possibilities

For storage tanks with choice of heating time, the heating elements must be reconnected according to the
wiring diagram glued inside the unit. The factory connection corresponds to a heating time of 6 hours in
~ 230 V supply voltage. The three-phase current circuits 3 ~ 400 V, respectively 3 N ~ 400 V, available as
an option for 100 litres and above, must also be reconnected according to the following table.

EKR

Reconnectable heating times, ratings and fusing current.
Bold figures represent the factory connection (6 hrs 230V)
Heater clamping* Heating
time hrs
Storage tank content
kW
100l
A
Storage tank content
kW
120l
A
Storage tank content
kW
150l
A
* S = side heater in flange
M = middle heater in flange

EKL

Bold figures represent the factory connection (6 hrs 230V)
Heater clamping*
Heating time hrs
Horizontal
storage
kW
tank content 80l
A
Horizontal
storage
kW
tank content 100l
A
Horizontal
storage
kW
tank content 120l
A
Horizontal
storage
kW
tank content 150l
A
Horizontal
storage
kW
tank content 200l
A
* S = side heater in flange
M = middle heater in flange
Heating times at mains voltage
~230V
S+M
M
S
6
16
8
1,75
1,10
2,20
10
6
2,00
1,35
2,70
10
10
2,30
1,65
3,30
16
10
Heating times at mains voltage
~230V
S+M
S
S+S
6
8
4
1,65
1,00
2,00
10
6
10
1,75
1,10
2,20
10
6
10
1,95
1,30
2,60
10
6
16
2,30
1,65
3,30
16
10
16
2,75
2,10
16
10
3~400V
S+M+S wye conn.
S+S
S+M+S
4
3 1/3
4
2,85
10
16
3,35
16
16
3,70
16
10
3~400V
S+M+S wye conn.
S+M+S
3 1/3
4
3 1/3
2,65
2,60
10
6
2,85
2,80
16
6
3,25
3,10
16
6
3,70
10
4,40
10
3N~400V
3 1/3
3 1/3
2,80
6
3,20
6
3,95
10
3N~400V
3 1/3
3,95
10
4,85
10
15
Id.Nr.: 228843-16