brennenstuhl RM L 3100 Schnellstart-Handbuch - Seite 3

Blättern Sie online oder laden Sie pdf Schnellstart-Handbuch für Rauchmelder brennenstuhl RM L 3100 herunter. brennenstuhl RM L 3100 3 Seiten. Battery operated photoelectric smoke detector with mute function

brennenstuhl RM L 3100 Schnellstart-Handbuch
Interpreting signals/troubleshooting
Display
Meaning
LED flashes once every
Indicates that the
40 seconds.
smoke detector is
working properly.
Continuous,
Alarm or test
pulsating tone. LED
function has been
flashes once per
triggered.
second.
LED flashes once every
The smoke detector
8 seconds.
has been muted.
LED flashes once every
The integrated
40 seconds, and the
battery is
device beeps.
weakening.
The device beeps
An error has
every 40 seconds
occurred
The device beeps
The smoke detector
three times every 1.5
is in test mode.
seconds.
LED flashes once every
The product has
10 seconds, and the
reached the end of
device beeps.
its lifespan.
Important:
Smoke detectors should be replaced after 10 years.
Evacuation plan
We recommend establishing an evacuation plan together with the other residents.
Think carefully about your evacuation route to make sure it cannot be blocked under any circumstances in the event of a fire. It must also
be the quickest and safest route into the open air.
Disposal
Do not discard the product in the regular household waste after it has reached the end of its lifespan. The product must be
dropped off at a collection point that
recycles electrical and electronic devices. Your municipality can provide you with information on how to dispose of the product
in a safe and environmentally friendly way.
Manufacturer's warranty
10 year manufacturer's warranty from date of purchase for labelled devices. Please keep the purchase receipt as verification. The
warranty only covers material or manufacturing defects of items that are used as intended. The warranty expires in the event of
unauthorized intervention. Your legal rights are not limited by this warranty.
Rechargeable batteries, batteries and illuminants included with an item are not included in the manufacturer's warranty.
Service address:
Hugo Brennenstuhl GmbH & Co. KG
Seestraße 1-3 D-72074 Tübingen www.brennenstuhl.com
Declaration of performance
Important: The Declaration of Performance is available for downloading on www.brennenstuhl.com, right next to item RM L 3100 / item
no 1290050.
Solution
- Leave the danger zone
at once.
- Release the test button
(if testing).
The smoke detector is
de-sensitised for approx.
10 minutes.
- This message can be
deactivated for 10
hours by pressing the
test button.
- The device must be
replaced at once.
- This message can be
deactivated for 10
hours by pressing the
test button.
- The device must be
replaced at once.
Release the test button
to end the test.
The device must be
replaced at once.