dymax BlueWave MX-250 Benutzerhandbuch - Seite 9
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Industrielle Ausrüstung dymax BlueWave MX-250 herunter. dymax BlueWave MX-250 16 Seiten. Led flood-curing emitter
Troubleshooting & Maintenance
Problem
BlueWave MX-250
LED does not
produce light
BlueWave MX-250
LED suddenly
stops producing
light
BlueWave MX-250
LED provides only
low-intensity light
U S E R G U I D E
B L U E W A V E M X - 2 5 0 E M I T T E R S
|
Possible Cause
LED intensity adjustment
set to 0% or too low
LED cycle time is set to
0 seconds
Interlock is open
Interface cable connections
loose or damaged
Trigger setting not
matched to input
LED head is not connected
to the correct port/channel
Over-temperature
shutdown was triggered
Footswitch defective
Interlock is open
LED intensity adjustment
set to minimum
Contaminated/dirty lens
optics
Corrective Action
Increase LED intensity setting.
0 Seconds sets manual mode and
requires a trigger.
Verify interlock jumpers are in place.
Verify PLC command structure for
PLC mode.
Check connections and condition of
interface cable.
Trigger setting on admin screen
should match the desired input trigger
channel.
Verify that the head is connected to the
desired port/channel.
Verify alarms.
Activate unit using the front control
panel. Replace the footswitch if the
unit operates from the front control
panel.
Verify interlock jumpers are in place.
Verify PLC command structure for
PLC mode.
Increase LED intensity setting on
admin settings or I/O input for PLC
mode.
Clean the surface of the lens.
9