6.
Plug the AC power cord into an AC power
outlet.
7.
When all connections are properly made, toggle
the power switch on the top of the BlueWave
AX-550 controller. The system is now ready for
use. Verify that the fan on the back of the light
shield is operating.
8.
Set the curing parameters according to
application requirements. Instructions for setting
these parameters and complete unit operation
can be found in the BlueWave
Curing System's User Guide.
9.
Open the light shield door, and verify "LED
INHIBIT OPEN" is displayed across the bottom
of the LCD screen (Figure 11). This indicates
that the light shield is connected and functioning
properly.
NOTE: Curing cycles cannot be started while
"LED INHIBIT OPEN" is displayed on the screen,
preventing accidental light exposure.
10. Estimate the height of the curing part in respect
to its base, or to the base of the part holder (if
the object to be cured is not free standing), and
then adjust the position of the tray to a proper
distance from the curing part. Use a ruler for
setting accuracy. You can set working distances
for each type of LED array assembly differently
to optimize your throughput with respect to
adhesive properties and irradiant energy
required to achieve the best curing quality in the
shortest time. Dymax Application Engineering is
ready to assist you if needed.
11. The system is ready for operation.
|
9
D Y M A X . C O M
®
AX-550 LED
®
Figure 11.
"LED INHIBIT OPEN" Indicates the Light Shield is
Connected and Functioning Properly
NOTE: If your unit doesn't display the "LED INHIBIT
OPEN" message on the screen when the Light
Shield door is opened, remove all power and do not
operate the unit. Contact Dymax for assistance
Door Open
Indication