WARNING:
Any other use is forbidden.
The GB585 and the GB585A are hydraulic installation tools designed specifically for the efficient installation of 5/8" and
3/4" HP8 or standard lockbolts. It weighs just under 20 lbs. (9.07 kg.). It has a 1.600" (40.6 mm) rivet stroke and a rated pull load
of 40,000 lbs. (177.9 kN).
The GB585 installation tool operates on hydraulic pressure developed by the GB940 Powerunit set at 5,400-5,700 psi
(372.3 - 393.0 bar) maximum PULL pressure and 2,200-2,400 psi. (151.7 - 165.5 bar) maximum RETURN pressure. The
tool comes equipped with 2 feet (.61 m) of hydraulic hoses and couplings, electric switch and cord.
The GB585A installation tool operates on hydraulic pressure developed by the GB910 & GB912 Powerunits set at 5,400-5,700 psi
(372.3 - 393.0 bar) maximum PULL pressure and 2,200-2,400 psi. (151.7 - 165.5 bar) maximum RETURN pressure. The tool
comes equipped with 2 feet (.61 m) of hydraulic hoses, swivels and couplings, air actuator and tube.
ALL GAGE BILT HYDRAULIC INSTALLATION TOOLS ARE COMPATABLE WITH HUCK® POWERUNITS. NOSE ASSEMBLIES ARE
NOT FURNISHED WITH THESE TOOLS AND MUST BE ORDERED SEPARATELY. (See nose assembly selection chart on pg. 15).
WARNING:
Do not operate in an explosive atmosphere.
The GB585 AND GB585A can be operated between 0ºF — 118ºF (-17.8ºC / 47.8ºC)
GB585 / GB585A INTALLATION TOOL
DESCRIPTION
ENVIRONMENTAL USE
SPECIFICATIONS
Weight
Hyd. Pressure Req'd.
Hyd. Power Source
Hydraulic Oil
Setting Stroke
Rated Pull Load
- 20 lbs. (9.07 kg)
- 5400 –5700 psi (372-3 - 393.0 bar) PULL
2200 –2400 psi (151.7- 165.5 bar) RETURN
- GB940, GB910 & GB912 Powerunits or equivalent.
- Fire resistant hydraulic oil conforming
with OSHA regulation 1926.302.
- 1.600" (40.6 mm)
- 40,000 lbs. (177.9 kN)
4