WARNING:
Only qualified and trained operators should install, adjust or use the assembly power tool for non-threaded
mechanical fasteners.
WARNING:
Operator
WARNING:
It is required that eye protection, hearing protection and safety boots be worn at all times while handling this
equipment.
WARNING:
The users or the user's employer should assess specific risks that could be present as a result after each use
based on their application.
● Be sure there is adequate clearance for tool and operator's hands before proceeding. Keep fingers clear of
any moving parts. Keep fingers clear from fasteners and installed materials. Severe personal injury may result.
● Verify
●
Ensure that there are no electrical cables, gas pipes, etc., which can cause a hazard if damaged by the tool
WARNING:
Do not pull rivet in the air. Personal injury from fastener ejecting may occur.
WARNING:
Air is exhausted from the bottom of the tool. Direct bottom of the tool (exhausted air) away from operator, other
persons working in the vicinity, foreign matter and liquid.
WARNING:
Do not carry from hoses or use as a hammer.
WARNING:
Do not use in explosive atmosphere.
WARNING:
Ensure air hose is securely connected to avoid possible hose whipping.
WARNING:
Always disconnect air supply when tool is not in use to prevent accidental start-up.
WARNING:
Be sure there is adequate clearance for tool and operator hands.
CAUTION:
Do not use beyond the design intent.
Lockbolts
#1. Insert fastener through the work piece.
#2. Slide collar over fastener.
WARNING:
Ensure air hose is securely connected to
avoid possible hose whipping (Air Actuated
Tools only).
#3. Insert fastener into nose assembly.
WARNING:
Be sure there is adequate clearance for
tool and operator hands.
#4. Press actuator to start cycle. Continue to press until fastener
breaks.
#5. Release actuator as soon as fastener breaks. Tool will then
push off collar and eject broken stem out the front of the
nose assembly.
#6. Repeat steps 1-5.
GB713
HOW TO USE THE GB713
MUST
read and understand all warnings and cautions.
the air lines and/or hydraulic hoses are not a trip hazard.
Images may not reflect actual tool or fastener
1.
Insert fastener.
2.
Insert rivet into nose assembly.
3.
Press actuator to start cycle. Continue to press until fastener
breaks.
4.
Release actuator as soon as fastener breaks. Tool will then
return to start position and pintail will be vacuumed through
evacuation tube.
5.
Repeat steps 1-4.
8
Blind Fasteners
7/11 REV 6/16