Features
1. 1/3" Sony Wide Dynamic image senor
2. Easy installation and special application
3. Support up to 8 privacy zone setting
4. Remote controllable for easy setting
5. 256X digital zoom for high quality picture
6. Advanced Day & Night mode with built-in Sony DSP chip for necessary
light level compensation.
7. Standard high quality audio
8. Power selection at AC100-240V or DC12V/AC24V
9. Offer image rotate function in both Horizontal and vertical.
10. Selectable picture display in normal and negative mode
11. 530 lines of high horizontal resolution
12. Minimum subject illumination of 0.003 lux @ F1.2
13. Automatic / Manual electronic shutter function 1/60 ~ 1/50,000 Seconds.
14. Digital slow shutter function available for special application.
Connection Interface-RS485
1. Connection:
RS
485 Interface
CAMERA
R+
1
R-
2
T+
3
T-
4
2. CAMERA and KEYBOARD PELCO P Connection: KEYBOARD ID must be
CAMERA ID+1
3. If Users changed the CAMERA ID from OSD MENU, users have to shut
down (exit) OSD menu once in order to make New CAMERA ID actives.
Keyboard(RS485)
Camera
Press CLOSE Key
Exit Sub Menu / Enter Sub Menu
Joystick Left
setting value decrease (-) at Sub Menu
Joystick Right
setting value increase (+) at Sub Menu
Joystick Up
Cursor Up
Joystick Down
Cursor Down
95 + Preset
Enter( /Exit)
7
5
PELCO P/D
D+
D-
Remark
OSD Mode
OSD Mode
OSD Mode
OSD Mode
OSD Mode
OSD Mode
Parts & Functions
8
VIDEO OUT
1
3
--
7
+
5
ON
OF
F
RS485
4
DC
VIDEO
AUDIO OU
T
2
DC +12V
6
1. Menu Selection Button:
* MENU button:Confirm button; long press means exit function.
*UP/DOWN button:Users are able to use Up/Down button select the
function that want to change from the menu list.
*LEFT/RIGHT button:Users are able to use Left/Right button to change
each function's setting.
2. Lens type:
Refer to lens type, users are able to choose best mode (DC, VIDEO or
AES) for their lens.
3. Remote Jack:
Provided RS485 connection interface
4. RS485 Terminal Switch
5. Power Indicator Light
6. Audio Output (RCA Jack)
7. Image Output (BNC Jack)
8. Auto IRIS Connector
9. Power Source:a. AC100V-AC240V ; b. DC12V/ AC24V; c. DC12V
6
Operations
※Normal Manual
In Normal Screen, Please use Up/Down button
for Digital Zoom Control.
Digital Zoom: 3X (WDR mode has to be OFF).
※In Normal screen, please press Menu button in order to access main menu.
O (MENU/Confirm Key)
※When users are initialing camera's settings, General menu's Camera ID、
Baud rate function, and Message menu's Zone function won't initial
camera's settings back to factory setting.
PS. The left key is back to root menu and right key is entry further menu.
Change menu option is moveable by up/down key.
Main MENU SETUP
BRIGHTNESS
50↓
EXPOSURE
ALC ↓
WHITE BAL
ATW1↓
BACKLIGHT
OFF↓
GAIN
ON ↓
SENS-UP
AUTO X8↓
SPECIAL
RESET
Exit