Replacement wick has a
black line.
Fold the new wick and slide it
into the holder.
Step 10
It is recommended to reinstall
the wick adjusting knob for
easier assembling.
Step 13
Snug 4 wing nuts on the
mounting stud, but do not
tighten.
Step 16
Check for correct clearance
between wick holder and draft
tube. It should be the same all
around.
Step 19
The black line on the outside of
the wick should match the top
edge of the holder.
Then press it against the teeth
inside the holder to obtain a
firm grip.
Step 11
Insert the pinion at the other end of
the wick control shaft into top portion
of the rack of the wick holder.
This step can be easily carried out if
the wick holder is raised.
Step 14
Raise the wick to the full "up"
position, and evently tighten wing
nuts in several steps.
Step 17
Check the function of safety
shut-off mechanism by pushing
the extinguish button to upset
the pendulum.
Step 20
11
Replace the wick and holder
in the burner tank.
Rotate 90 degrees left and
right as well as up and down
until the wick slides freely.
Check to see that gasket is
still in place on the burner tank.
Step 12
Slide the wick abjuster
assembly down the draft tube.
Position the adjuster shaft to
the front of the heater.
Step 15
Check height of wick.
It should be 5/16"above collar.
Step 18
Reinstall the automatic ignition
assembly.
Step 21