Dynablast MHGE500SQ Benutzerhandbuch - Seite 7

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Hochdruckreiniger Dynablast MHGE500SQ herunter. Dynablast MHGE500SQ 17 Seiten. Hot water pressure washers

SAFETY COMPONENTS

SQN/P
SERIES
FLOW SWITCH
The flow switch prevents the burner from being turned on if there is insufficient water. Proper water flow causes
the magnetic core to be pushed up, closing the reed contact. This contact is interlocked with the fuel solenoid
valve in the oil pump.
SAFETY RELIEF VALVE
The Relief Valve prevents the machine from being subjected to abnormally high pressures. If this situation occurs,
the valve will blow off relieving the pressure in the coil. This valve may also operate if the unloader is adjusted too
high.
THERMOSTAT
The built-in thermostat stops the unit from overheating. Maximum temperature of the unit is 212°F.
HIGH LIMIT SWITCH
The High Temperature Limit Switch is a thermostat which is set to 230°F. This switch is not adjustable and will
only operate when other controls fail to keep the water temperature within the normal operating range. This
switch cuts the power to the fuel solenoid
4