Aircommand HERON 2.2 Installationsanleitung Handbuch - Seite 8
Blättern Sie online oder laden Sie pdf Installationsanleitung Handbuch für Klimagerät Aircommand HERON 2.2 herunter. Aircommand HERON 2.2 10 Seiten.
Auch für Aircommand HERON 2.2: Benutzerhandbuch (17 seiten)
OPERATING INSTRUCTIONS
This appliance is not intended for use by young children or infirm persons without supervision. Young
children should be supervised to ensure that they do not play with this appliance.
This airconditioner may be used in cooling mode with outside temperatures from 18ºC to 48ºC, and inside
temperatures from 18ºC to 30ºC. In heating mode, the airconditioner may be used with outside and inside
temperatures up to 30ºC.
COOLING: (ref fig.16)
NB. The unit will not run on cooling if the inside temp. is much below 18°C.
1. Turn fan speed selector to
2. Turn mode selector to
3. Adjust the thermostat counter clockwise until the condenser set is heard to start.
4. Gradually over time, adjust the thermostat until comfortable conditions are maintained.
AVOID RESTARTING THE COMPRESSOR WITHIN 3 MINUTES OF TURNING OFF
HEATING: (ref fig.16)
NB. The unit will not heat if inside temp. is much above 28°C.
1. Turn fan speed selector to
2. Turn mode selector to
3. Adjust the thermostat to max. clockwise position.
There will be approximately 30 seconds delay before heating is apparent.
4. Gradually over time, adjust the thermostat until comfortable conditions are maintained.
Condenser set:
Height
-
Width
-
Depth
-
Weight -
Air Handler:
Height
-
Width
-
Depth
-
Weight -
Minimum cupboard dimensions:
320 high x 525 wide x 300 deep
Cooling output:
Heating output:
Maximum current (cooling):
Maximum current (heating):
Maximum locked rotor current:
(Hi Speed Cooling)
(Cooling)
(Heating Speed)
(Heating)
UNIT SPECIFICATIONS
235 mm Above floor
460 mm
440 mm
30 kg
220 mm
385 mm
230 mm
4 kg
2.2 KW
1.5 KW
4.0 amps
6.5 amps
19 amps
Refrigerant:
Australia only
Euro production
Charge:
Air volume (max) Air Handler:
Compressor:
Resistance run wdg.:
Resistance start wdg.:
Capacitor:
Fan (Air handler):
Resistance run wdg.:
Resistance aux wdg.:
Capacitor:
Fan (Condenser set):
Resistance run wdg.:
Resistance aux wdg.:
Capacitor:
Heating element:
Refer fitting instructions included
8
R22
R407C
650 grms.
110 l/s
Sanyo KR6102
2.8Ω
4.3Ω
20 mfd. 440 vac
165Ω
265Ω
1.5 mfd. 440 vac
168Ω
150Ω
2.5 mfd. 440 vac
1500W
(Pt. No. 4002024)