Gaggenau VG 233 234 CN Einbauanleitung - Seite 4

Blättern Sie online oder laden Sie pdf Einbauanleitung für Kochfeld Gaggenau VG 233 234 CN herunter. Gaggenau VG 233 234 CN 4 Seiten.

Gaggenau VG 233 234 CN Einbauanleitung
en
Ú Installation instructions
Important notes
Read these instructions carefully and keep them in a safe place.
Safety during use can only be ensured if the appliance is fitted
correctly according to these installation instructions. The installer
is responsible for ensuring that the appliance operates perfectly at
the point of installation.
The appliance must be connected to the mains only by a licensed
and trained technician.
Before carrying out any type of work, turn off the electricity and gas
supply.
For installation, currently applicable building regulations and the
regulations of local electricity and gas suppliers must be observed.
For conversion to another type of gas, please call the after-sales
service.
Risk of gas escape!
After connecting the appliance to the gas supply, always check the
connection for leak tightness. The manufacturer accepts no
responsibility for the escape of gas from a gas connection which
has been previously tampered with.
Ensure sufficient air exchange in the room where the appliance is
installed. Up to 11 kW total output:
Minimum volume of the room where appliance is installed: 20 m³
A door leading to the open air or a window which can be opened.
Up to 18 kW total output:
Minimum volume of the room where appliance is installed: 2 m³
per kW total output.
A door leading to the open air or a window which can be opened.
An extraction hood into the open air. Minimum displacement
volume of extraction hood: 15 m³/h per kW total output.
The installation system must incorporate an all-pin isolating switch
with a contact opening of at least 3 mm, or the appliance should be
connected to the mains via a safety plug. The plug must remain
accessible after installation is complete.
Specifications on the rating plate showing voltage, type of gas and
gas pressure must agree with the local mains connection
conditions.
Do not kink or trap the mains connection cable.
This appliance corresponds to appliance class 3 (for installation in
a kitchen unit). It must be fitted according to the installation
drawing. The wall behind the appliance must be made of non-
flammable material.
This appliance is not intended for operation with an external timer
or an external remote control.
Do not install this appliance on boats or in vehicles.
Preparing the furniture
The surrounding kitchen unit must be heat-resistant to at least
90 °C. The stability of the unit must be maintained after producing
the cut-out.
Produce the cut-out for the appliances. Proceed as shown in the
installation sketch. The dimensions in the installation sketch allow
for the additional space required for the connecting strip. The
angle between the cut surface and the worktop must be 90°.
After producing the cut-out, remove the shavings. Seal the cut
surfaces to make them heat-resistant.
Observe a minimum clearance between the appliance housing
and parts of the unit of 10 mm.
The connecting strip VV 200 has to be ordered separately.
Appliances can also be fitted in individual recesses, if a minimum
clearance of 40 mm between the appliances is observed.
Fitting the appliance
1.
Mark the distance to the centre of the appliances as shown in the
installation sketch. Fit the mounting rails to the front and rear of
the recess. Make sure the lugs of the mounting rails lie on the
worktop. The centre marking on the mounting rails must be
precisely flush with the centre markings of the recess.
Note: when fitting the appliance in a stone worktop glue on the
mounting rails with a temperature-resistant two-component
adhesive (metal on stone).
2.
For combination with the appliance cover VD 201: secure the
appliance cover on the appliance before installation (refer to the
installation manual of VD 201).
3.
Lower the first appliance into the cut-out. The snap-in pins on the
appliance must lie exactly on the catch springs. Firmly press the
appliance into the cut-out. The pins on the appliance must snap
into the catch springs.
4.
Put the second appliance onto the securing rails and check that
the gap between the control panels is between 4.5 and 5.0 mm.
If the distance is not exactly right, take out the second appliance
again and loosen the screws of the installation rails. You can now
move the rails in the oblong holes. Then tighten the screws again.
5.
Firmly press the second appliance onto the securing rails. Place
the connecting trim VV 200 between the appliances and press it
in (see installation guide of VV 200).
Removing the appliance
Disconnect the appliance from the power and the gas supply.
Push out the appliance from below.
Caution!
Risk of damage! Do not lever out the appliance from above.
Gas connection
The gas connection must be located in a position where the stop
tap is accessible.
Using one of the R½'' (for appliance side) connection elbows
provided, connect the appliance with the associated gasket to a
fixed connection pipe or a gas safety hose. If the gas safety hose
is not (or only partly) made of metal, the ambient temperature must
not exceed 70°K. In the case of a gas safety hose made entirely of
metal, the permissible ambient temperature is 115°K. The gas
safety hose must be routed so that it does not come into contact
with moving parts of the kitchen unit (e.g. drawers).
Electrical connection
Check that the appliance has the same voltage and frequency as
the electrical installation system.
The hob is delivered with a mains cable, with or without plug,
depending on model.
Only connect the appliance to sockets which have been fitted and
earthed according to regulations.
The appliance corresponds to type Y: the mains connection cable
must only be replaced by the after-sales service. Check the cable
type and minimum cross section.
Technical data
Wok burner:
Level 4 full burning (outer), full burning (inner)
5.2 kW(Hi) / 5.9 kW(Hs)
Level 3 low burning (outer), full burning (inner)
1.35 kW(Hi) / 1.5 kW(Hs)
Level 2 full burning (inner)
0.45 kW(Hi) / 0.5 kW(Hs)
Level 1 low burning (inner)
<0.23 kW(Hi) / 0.25 kW(Hs)
High-intensity burner:
Full burning
2.52 kW(Hi) / 2.80 kW(Hs)
Low burning
<0.50 kW(Hi) / 0.56 kW(Hs)
Normal burner:
Full burning
1.71 kW(Hi) / 1.90 kW(Hs)
Low burning
<0.34 kW(Hi) / 0.38 kW(Hs)
Gas connection:
R½" union nut for R½" bracket to DIN 1999, conical-cylindrical
Electric:
Rated consumption: 1.6 W
Voltage: 220 - 240 V
Frequency: 50 - 60 Hz
Technical modifications reserved.