Fig. 21
Fig. 22
16
6. Adjust the support frame to the desired height
and secure with 8 screws. The length of the
support frame can be adjusted in steps of
20 mm from 386 mm to 646 mm (Fig. 21).
Note:
ensure that the minimum distance between the
hob and the extractor hood is maintained -
600 mm for an electric hob and 700 mm for a
gas hob
7. Stainless steel ventilation ducts only
(LK 590-010/020/030):
pull the protective film off the metal surface.
8. Place both ventilation ducts over the support
frame. Take care not to scratch the sensitive
duct surface.
9. Attach the electrical plug to the support frame
with sticky tape so that it can be easily reached
later.
10. Hang the hood and the support frame with the
two key-holes to the two screws in the ceiling
(Fig. 22).
Attention: the two screws cannot support
the weight of the hood. Therefore it must be
supported at this stage!