Dynabrade Dynorbital-Spirit 59113 Sicherheit, Betrieb und Wartung - Seite 2
Blättern Sie online oder laden Sie pdf Sicherheit, Betrieb und Wartung für Sander Dynabrade Dynorbital-Spirit 59113 herunter. Dynabrade Dynorbital-Spirit 59113 13 Seiten. 12,000 rpm random orbital sander
Auch für Dynabrade Dynorbital-Spirit 59113: Sicherheit, Betrieb und Wartung (4 seiten), Sicherheit, Betrieb und Wartung (8 seiten)
• Keep hand and clothing away from working end of the air tool.
Operation: Be sure that any loose clothing, hair and all jewelry is properly restrained.
• Secure inlet bushing on air tool with a wrench before attempting to install the air fitting to avoid damaging housing assembly.
• Check tool RPM (speed) with tachometer with air pressure set at 90 PSIG while the tool is running. If tool is operating at a higher speed than the RPM marked on the tool
housing, or operating improperly, the tool must be serviced and corrected before use.
Caution: Tool RPM must never exceed abrasive/accessory RPM rating. Check accessory manufacturer for details on maximum operating speed or special
mounting instructions.
• With power source disconnected from air tool, mount recommended accessory into collet assembly.
• Connect air tool to power source. Be careful NOT to depress throttle lever in the process. Do not expose air tool to inlet pressure above 90 PSIG or (6.2 Bars).
Caution: After installing the accessory, before testing or use and/or after assembling tool, the Dynorbital-Spirit™ must be started at a reduced speed to check for good
balance. Gradually increase tool speed. DO NOT USE if tool vibration is excessive. Correct cause, and retest to insure safe operation.
• Make sure that work area is uncluttered, and visitors are at a safe range from the tools and debris.
• Use a vise or clamping device to hold work piece firmly in place.
• Do not apply excessive force on tool or apply "rough" treatment to it.
• Always work with a firm footing, posture and proper lighting.
Report to your supervisor any condition of the tool, accessories, or operation you consider unsafe.
Regulator
Filter
• Dynabrade Air Power Tools are designed to
operate at 90 PSIG (6.2 Bar/620 kPa) maximum
air pressure at the tool inlet, when the tool is
running. Use recommended regulator to control
air pressure.
OPERATING INSTRUCTIONS (continued)
Air System
90 PSIG
(6.2 Bar)
Closed Loop Pipe System
(Sloped in the direction of air flow)
To Tool Station
Regulator
Filter
Lubricator
Ball
Valve
➤
Drain
Valve
Drain
Valve
Coupler
Air Tool
90 PSIG MAX
(6.2 Bar)
Lubricator
Ball
Valve
Air Hose
Air Flow
Air Compressor
and Receiver
Drain Valve
• Ideally the air supply should be free from moisture.
Incorporating a refrigerated air dryer after the
compressor and drain valves at each tool station
(as shown) further reduces moisture from
condensation in the air supply.
2
LUBRICATOR SETTING
1 DROP/MIN.
10 SCFM
Air Flow
Refrigerated
Air Dryer