Dynabrade 52213 Handbuch - Seite 2

Blättern Sie online oder laden Sie pdf Handbuch für Schleifer Dynabrade 52213 herunter. Dynabrade 52213 4 Seiten. .5hp/7˚/front exhaust/short shank die grinder
Auch für Dynabrade 52213: Betriebsanleitung (4 seiten), Handbuch (4 seiten)

Dynabrade 52213 Handbuch
Important Operating, Maintenance and Safety Instructions
Carefully read all instructions before operating or servicing any Dynabrade
Warning:
Hand, wrist and arm injury may result from repetitive work motion and overexposure to vibration.
Warning:
Eye, face, sound, respiratory and body protection must be worn while operating power tools. Failure to do so may result in serious
injury or death. Follow safety procedures posted in workplace.
1.
With power source disconnected from tool, securely fasten abrasive/accessory on tool.
2.
Install air fitting into inlet bushing of tool.
damaging valve body housing.
3.
Connect power source to tool. Be careful not to depress throttle lever in the process.
4.
Air tools are not intended for use in explosive atmospheres and are not insulated for contact with electrical power sources. Sanding/Grinding certain
materials can create explosive dust. It is the employers responsibility to notify the user of acceptable dust levels. Sanding/Grinding can cause sparks
which can cause fires or explosions. It is the users responsibility to make sure the work area if free of flammable materials.
1.
Check tool speed regularly with a tachometer. If tool is operating at a higher speed than the RPM marked on the tool, the tool should be
serviced to correct the cause before use.
2.
Some silencers on air tools may clog with use. Clean and replace as required.
3.
Use only genuine Dynabrade replacement parts. To reorder replacement parts, specify the
4.
A Motor Tune-Up Kit (P/N
Dynabrade's Preventative Maintenance Schedule for a guide to expectant life of component parts.
5.
It is strongly recommended that all Dynabrade rotary vane air tools be used with a Filter-Regulator-Lubricator to minimize the possibility of misuse due to
unclean air, wet air or insufficient lubrication. Dynabrade recommends the following:
pressure regulation, two-stage filtration of water contaminants and micro-mist lubrication of pneumatic components.
Operates 40 SCFM @ 100 PSIG has 3/8" NPT female ports.
6.
Mineral spirits are recommended when cleaning the tool and parts. Do not clean tool or parts with any solvents or oils containing acids, esters
keytones, chlorinated hydrocarbons, nitro carbons or chemicals that have a low flash point (example: WD-40
Products offered by Dynabrade should not be converted or otherwise altered
from original design without expressed written consent from Dynabrade, Inc.
Important:
User of tool is responsible for following accepted safety codes such as those published by the American National
Standards Institute (ANSI).
Always disconnect power supply before changing abrasive/accessory or making machine adjustments.
Inspect abrasives/accessories for damage or defects prior to installation on tools.
Please refer to Dynabrade's Warning/Safety Operating Instructions Tag (Reorder No.
All Dynabrade motors use the highest quality parts and metals available and are machined to exacting tolerances. The failure of quality pneumatic motors can
most often be traced to an unclean air supply or the lack of lubrication. Air pressure easily forces dirt or water contained in the air supply into motor bearings
causing early failure. It often scores the cylinder walls and the rotor blades resulting in limited efficiency and power. Our warranty obligation is contingent upon
proper use of our tools and cannot apply to equipment which has been subjected to misuse such as unclean air, wet air or a lack of lubrication during the use
of this tool.
Following the reasonable assumption that any inherent defect which might prevail in a product will become apparent to the user within one year from the
date of purchase, all equipment of our manufacture is warranted against defects in workmanship and materials under normal use and service. We shall
repair or replace at our factory, any equipment or part thereof which shall, within one year after delivery to the original purchaser, indicate upon our
examination to have been defective. Our obligation is contingent upon proper use of Dynabrade tools in accordance with factory recommendations,
instructions and safety practices. It shall not apply to equipment which has been subject to misuse, negligence, accident or tampering in any way so as to
affect its normal performance. Normally wearable parts such as bearings, sanding pads, rotor blades, etc., are not covered under this warranty.
Model Number
Motor
Motor
1/4" / 6mm
HP (W)
RPM
52210
52260
/
.5 (373)
15,000
52211
52261
/
.5 (373)
18,000
52212
52262
/
.5 (373)
20,000
52213
52263
/
.5 (373)
24,000
Additional Specifications: Air Pressure 90 PSIG (6.2 Bar)
Important:
Secure inlet bushing of tool with a wrench before attempting to install the air fitting to avoid
96044
) is available which includes assorted parts to help maintain motor in peak operating condition. Please refer to
Sound
Maximum Air Flow
Level
CFM/SCFM (LPM)
78 dB(A)
4/26 (736)
77 dB(A)
4/28 (793)
77 dB(A)
4/28 (793)
82 dB(A)
4/28 (793)
Abrasive Power Tool.
®
Model #
11405
Air Line Filter-Regulator-Lubricator — Provides accurate air
95903
) for more complete safety information.
Hose
Air Inlet
I.D. Size
Thread
3/8" or 10mm
1/4" NPT
3/8" or 10mm
1/4" NPT
3/8" or 10mm
1/4" NPT
3/8" or 10mm
1/4" NPT
(PD01•01)
2
Serial #
RPM
,
, and
of your machine.
).
®
Tool
Weight
Thread
Pound (kg)
3/8"-24 Male
1.7 (0.8)
3/8"-24 Male
1.7 (0.8)
3/8"-24 Male
1.7 (0.8)
3/8"-24 Male
1.7 (0.8)
Length
Height
Inch (mm)
Inch (mm)
6 (152)
4-1/2 (114)
6 (152)
4-1/2 (114)
6 (152)
4-1/2 (114)
6 (152)
4-1/2 (114)