Hi-Tech Cloud Benutzerhandbuch - Seite 6

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Water Filtration Systems Hi-Tech Cloud herunter. Hi-Tech Cloud 8 Seiten.

PRECAUTIONS
1.)
After plugging it, make sure the raw water tank and pure water kettle are in the right
place.
2.)
Check if the LCD works well.
3.)
Using the machine first time or after changing the filters, the pure water will be dirty
with black color as new CTO flushing. It is normal for 1-3 bottles. So follow the flushing
procedure as previously mentioned.
4.)
Make sure the raw water tank has enough water but not over the maximum level.
7. Maintenance
■ Recommended replacing period for the filters based on basic tap water :
PP 5 miu Sediment Filter
6 month
CTO Filter
6 month
HI-TECH RO Membrane
2 years
12 months
Post Filter - CCF
■ Should replace filters under the following circumstances :
SYMTOMS
The water making is too slow
1.)
(more then 15 minute for 1 Kettle)
The water production is too fast
2.)
(less then 5 minute for 1 Kettle)
3.)
The water tastes is not good
The removal rate of the membrane is
4.)
less than 75%
07
REASONS
first two pre-filter or the membrane
are blocked
The membrane is damaged
The post filter life expires
RO Membrane life is expires
■ Replacing Filters
1.)
Plug out the cord for cutting electricity connection, and remove the water
from RAW Water Tank and Pure water glass kettle.
2.)
Open the filter cover.
3.)
Hold the filter little outside and screw it left-handed way to remove.
4.)
There is a trapezium on the filter. Adjust it to the triangle on the filter cap
and screw it to the cap right-handed tightly.
Open filter cover
Turn left and move filter Turn right and fix filter
8. Packing List
CLOUD RO apparatus
Pure Water Kettle
Manual
Wire(AC220V/DC24V)
1 set
1
1 copy
1
08