Gaggenau RB 292 Betriebsanleitung - Seite 18

Blättern Sie online oder laden Sie pdf Betriebsanleitung für Kühlschrank Gaggenau RB 292 herunter. Gaggenau RB 292 20 Seiten.
Auch für Gaggenau RB 292: Gebrauchsanweisung Handbuch (19 seiten)

Gaggenau RB 292 Betriebsanleitung
Fault
Freezer compartment door
was open for a long time;
temperature is no longer
reached.
18
Possible cause
The evaporator (refrigeration
generator) in the No Frost system
is covered in thick ice and can no
longer be defrosted fully
automatically.
Remedial action
To defrost the evaporator, remove the frozen
food with the compartments, insulate well and
store in a cool location. Switch off the
appliance and move it away from the wall.
Leave the appliance door open.
After approx. 20 min. the condensation begins
to run into the evaporation pan, at the rear of
the appliance.
To prevent the evaporation pan from
overflowing in this case, mop up the
condensation with a sponge.
The evaporator is defrosted when the water
stops running into the evaporation pan.
Clean the interior. Switch the appliance back
on again.