Dynabrade 61201 Anweisungen zu Sicherheit, Betrieb und Wartung - Seite 10
Blättern Sie online oder laden Sie pdf Anweisungen zu Sicherheit, Betrieb und Wartung für Staubsauger Dynabrade 61201 herunter. Dynabrade 61201 12 Seiten. Electric drum vacuum
(B) BLACK ELECTRIC SWITCH (I O II)
(select different working modes)
MODE "0": machine is off
MODE "I": the motors are working with cyclic cleaning of the cartridge filter
MODE "II": Electric control system is in automatic mode and the cleaning of the cartridge filter are working.
When the tool is switched off, after about 4 seconds the vacuum cleaner motor will switch off.
•
The manufacturer is not responsible for damages to people or things due to an incorrect or negligent use of the ELECTRIC auto on/off device.
•
Changes in the electrical connection of the vacuum head could cause serious damages, even the death of the operator, and irreparable damages
to the vacuum head.
WHITE SLIDE SWITCH (I II) (optional)
POSITION "I": low speed
1 user – 1 flexible hose
POSITION "II": high speed
2 users – 2 flexible hoses
ORANGE INDICATOR LIGHT
Connected to a pressure switch, when it lights means that the cartridge filter (essential filter) is clogged
and it must be replaced.
RED INDICATOR LIGHT
It turns on when the thermal protection that stops the motor is activated. The thermal protection works
when the temperature of the air coming out from the motor is about 85°C. The motor overheating is due
to an obstructed filter cartridge.
COMPONENTS AND FEATURES
Description of Electric Controls
WARNING
10